Transcutaneous implants: Reactions of the skin-implant interface
✍ Scribed by Winter, George D.
- Publisher
- John Wiley and Sons
- Year
- 1974
- Tongue
- English
- Weight
- 953 KB
- Volume
- 8
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
One method of providing an artificial limb for an amputee might be to attach the external prosthesis directly to the skeleton but a major problem is the behavior of the tissues at the point where the prosthesis penetrates the skin surface. Preliminary experiments have been carried out using small flexible implants in porcine skin to study the principles involved. It is confirmed that the epidermis grows down into the dermis around the nonporous materials and the implant‐skin junction is unstable and readily becomes infected. It was found that polytetrafluorethylene with pores of 10 μm diameter and hydron sponge with pores of 40 μm diameter became invaded by fibrous tissue and this appeared to prevent the migration of epidermis alongside the implants and a stable ring of epidermal tissue was formed near the skin surface. A review of other situations where epidermal migration is taking place suggests that epidermis is able to migrate through damaged collagenous tissue, possibly with the help of leucocytic enzymes, but that epidermal cell movement is halted when the epidermal sheet is confronted by heathly collagen bundles.
📜 SIMILAR VOLUMES
## Abstract Three‐dimensional finite element analysis (FEA) has been used to determine the implant‐bone interface characteristics of bioglass dental implants. The results of the FEA were verified by comparison with the results of mechanical testing performed on animal implant specimens. The results
## Abstract The lymphatic system plays an essential physiological role in homeostasis, interstitial fluid composition, and immunity while impaired lymphatic function has been implicated in a number of pathological conditions, including arthritis and delayed wound healing. This study investigated ly
## Abstract The interfacial shear properties of bone tissue growth into porous coated Ti‐6A1‐4V femoral implants have been examined as a function of the pore size of the porous surface. Three particle size range powders (297 μm, 420–500 μm, 595–707 μm) were used to fabricate cylindrical implants wh
A new swelling copolymeric material suitable for self-anchoring bone implants was introduced in part I of this two-part article. The main goal in the second part of the study was to investigate the in vitro fixation characteristics of these novel implants in bone using push-out mechanical testing. S