## Abstract A shift comparison procedure, which allows the use of flow spectra in automatic structure confirmation, is described. The effect of imperfect proton scaling at the analysis stage, loss of solute resonances under large solvent signals and the intermittent detection of labile protons are
Towards the automatic analysis of 1H NMR spectra: Part 3. Confirmation of postulated chemical structure
β Scribed by Lee Griffiths; Jonathan D. Bright
- Publisher
- John Wiley and Sons
- Year
- 2002
- Tongue
- English
- Weight
- 167 KB
- Volume
- 40
- Category
- Article
- ISSN
- 0749-1581
- DOI
- 10.1002/mrc.1063
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
A method is proposed which automatically compares experimental and predicted ^1^H chemical shifts, integrals and scalar couplings and allows the structure on which the predictions are based to be confirmed or refuted. The method is comparatively insensitive to the variable presence of labile protons but is sensitive to the reliability of chemical shift prediction. Nonetheless, even with current commercially available ^1^H chemical shift prediction, amongst a set of unrelated compounds the structure can be confirmed with 99% confidence. Where the compounds are closely related, the confidence decreases to approximately 60%, or 88% when labile protons are excluded. If closely related pairs are nominated explicitly, a specific criterion can be set for each pair, allowing every pair to be differentiated. Copyright Β© 2002 John Wiley & Sons, Ltd.
π SIMILAR VOLUMES
A method of comparing predicted and experimental chemical shifts was used to confirm or refute postulated structures. 1H NMR spectra returned all true positives with a false positive rate of 4%. When an analogous procedure was adopted for 13C NMR spectra, the false positive rate dropped to 1%, where
## Abstract FlowβNMR allows more rapid and convenient acquisition of NMR spectra. Its main application area has therefore been in multiple parallel synthesis or combinatorial chemistry. At the same time, there is a significant need to automate the analysis of the resultant spectra. However, flowβNM
## Abstract A method was developed for the extraction of accurate NMR integrals, even where partially convoluted with other solute or solvent resonances, and then automatically allocating these to multiplets. The method yields an overall error of 7%, an assessment which includes a statistical distr
## Abstract A reliable method of automatically assigning oneβdimensional proton spectra is described. The method relies on the alignment of the proton spectrum with an associated heteronuclear singleβquantum coherence (HSQC) spectrum, transferring the stoichiometry and couplings to the HSQC. The HS