𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Toward optimal use of the cytology laboratory: Quality improvement and cerebrospinal fluid specimens

✍ Scribed by Ann E. Walts; Stephen Strigle


Publisher
John Wiley and Sons
Year
1995
Tongue
English
Weight
409 KB
Volume
13
Category
Article
ISSN
8755-1039

No coin nor oath required. For personal study only.

✦ Synopsis


Review of 203 consecutive cerebrospinal fluid (CSF) specimens submitted concurrently to the cytology and hematology laborato-

ries identified several quality improvement (QI) opportunities. Clinician/laboratoiy, interlaboratory, and intralaboratory issues are addressed. Data are utilized to formulate a multifaceted approach that would decrease patient expenditure, conserve laboratory re-


📜 SIMILAR VOLUMES


Improving the diagnostic accuracy of cyt
✍ Kalyani Desai; Margaret A. Fallon; Deborah Willard-Smith; David C. Wilbur 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 154 KB 👁 2 views

In patients with acute lymphoblastic leukemia (ALL), cytologic examination of cerebrospinal fluid (CSF) is becoming increasingly important for clinical management. In order to enhance the diagnostic accuracy of CSF cytology results, the value of using terminal deoxynucleotidyl transferase (Tdt) and

Use of statistical analysis of cytologic
✍ Renshaw, Andrew A. ;Lee, Kenneth R. ;Granter, Scott R. 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 149 KB 👁 2 views

## Background: Disagreements in cytologic interpretation can have several causes, including differences in diagnostic threshold and diagnostic accuracy. these can be distinguished by a combination of statistical analyses. ## Methods: For demonstration purposes, a nonrandom collection of 80 cervic

Quantitation of cytomegalovirus DNA in c
✍ David Tarragó; María-Luisa Mateos; Ana Avellón; María-Dolores Pérez-Vázquez; Ant 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 190 KB

## Abstract A novel nested quantitative‐competitive polymerase chain reaction (nQC‐PCR) assay was developed to quantify as few as ten copies per tube of human cytomegalovirus DNA with an overall dynamic range of 10–10^5^ copies per tube. This nQC‐PCR assay is based on co‐amplification of a mimic DN

Application of an improved biuret method
✍ Xu Guobing; Jiao Lili; Zhu Lihua; Xia Tiean 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 47 KB

## Abstract A biuret automated colorimetric assay for total protein in urine and cerebrospinal fluids was established. The procedures were as follows. Acidify all urine sample before analysis. Add precipitant Na~2~WO~4~ to urine samples. After 10 min, centrifuge, decant the supernatant fluid, drain