𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Time-resolved bolus-chase MR angiography with real-time triggering of table motion

✍ Scribed by Casey P. Johnson; Clifton R. Haider; Eric A. Borisch; James F. Glockner; Stephen J. Riederer


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
577 KB
Volume
64
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Time‐resolved bolus‐chase contrast‐enhanced MR angiography with real‐time station switching is demonstrated. The Cartesian acquisition with projection reconstruction‐like sampling (CAPR) technique and high 2D sensitivity encoding (SENSE) (6× or 8×) and 2D homodyne (1.8×) accelerations were used to acquire 3D volumes with 1.0‐mm isotropic spatial resolution and frame times as low as 2.5 sec in two imaging stations covering the thighs and calves. A custom real‐time system was developed to reconstruct and display CAPR frames for visually guided triggering of table motion upon passage of contrast through the proximal station. The method was evaluated in seven volunteers. High‐spatial‐resolution arteriograms with minimal venous contamination were consistently acquired in both stations. Real‐time stepping table contrast‐enhanced MR angiography is a method for providing time‐resolved images with high spatial resolution over an extended field‐of‐view. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Time-resolved 3D MR angiography of the a
✍ Oliver Wieben; Thomas M. Grist; Thomas F. Hany; Frank J. Thornton; John K. Glase 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 350 KB

## Abstract This study reports on the implementation of a real‐time MR acquisition, reconstruction, and display system on standard hardware for 3D contrast‐enhanced MR abdominal angiography. The system allows for dynamic imaging of the contrast passage with good spatial resolution in a single breat

Single-dose time-resolved contrast enhan
✍ Chun-Chieh Wang; Huei-Lung Liang; Chia-Chi Hsiao; Matt Chiung-Yu Chen; To-Ho Wu; 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 340 KB 👁 1 views

## Abstract ## Purpose To prospectively study the diagnostic performance of hybrid single‐dose contrast‐enhanced MRA of peripheral arterial disease (PAD), with digital subtraction angiography (DSA) as the reference standard. ## Materials and Methods Hybrid MRA, combining time resolved imaging of

Effect of chronic hypoxia on pulmonary a
✍ Eric Dumas de La Roque; Eric Thiaudière; Thomas Ducret; Roger Marthan; Jean-Mich 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 323 KB

## Abstract Pulmonary arterial hypertension (PAH) is a severe disease that leads to increased pulmonary vascular resistance and right heart failure. Noninvasive methods are needed to detect changes in the pulmonary artery circulation during PAH establishment and/or treatment. Pulmonary blood flow v

Time-resolved, high-resolution contrast-
✍ Katja A. Mende; Johannes M. Froehlich; Constantin von Weymarn; Romhild Hoogeveen 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 513 KB

## Abstract ## Purpose To evaluate the use of a dynamic keyhole magnetic resonance angiography (MRA) sequence combined with sensitivity encoding (SENSE) for hemodialysis shunts, because surveillance with conventional contrast‐enhanced MRA (CE‐MRA) is limited by its low temporal resolution, resulti

Real-time MR imaging of myocardial regio
✍ El-Sayed H. Ibrahim; Matthias Stuber; Ahmed S. Fahmy; Khaled Z. Abd-Elmoniem; Te 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 744 KB

## Abstract ## Purpose To implement real‐time myocardial strain‐encoding (SENC) imaging in combination with tracking the tissue displacement in the through‐plane direction. ## Materials and Methods SENC imaging was combined with the slice‐following technique by implementing three‐dimensional (3D