๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Thrombogenic properties of arterial catheters: A scanning electron microscopic examination of the surface structure

โœ Scribed by Thomsen, Henrik Klem ;Kjeldsen, Knud ;Hansen, Jorgen Fischer


Publisher
John Wiley and Sons
Year
1977
Tongue
English
Weight
600 KB
Volume
3
Category
Article
ISSN
0098-6569

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

We performed 300 consecutive coronary arteriographies with 2 different kinds of catheters: polyurethane catheters and polyethylene catheters. The thromboembolic complication rate for investigations with each type of catheters is compared to the surface structure as seen with the scanning electron microscope (SEM). The complication rate was 21.4% for polyurethane catheters and 0.3% for polyethylene catheters. The inner surface of polyurethane catheters was irregular, while the inner surface of polyethylene catheters appeared smooth. The outer surface of polyurethane catheters was slight irregular, while the outer surface of polyethylene catheters was smooth. These results are compared to other investigations of the surface structure of coronary catheters and to reports on the thromboembolic complication rate at coronary arteriography. It is concluded that the 2 types of catheters have different thrombogenic properties and that the surface structure is of major importance for this difference.


๐Ÿ“œ SIMILAR VOLUMES


A scanning electron microscopic study on
โœ Doris Moser; Michael Rasse; Christian Schopper; Georgios Lagogiannis; Michael Fr ๐Ÿ“‚ Article ๐Ÿ“… 2002 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 375 KB

## Background: The purpose of this study was to assess the impact of standard anticoagulation and intermittent catheter irrigation on clot formation on intraarterial chemotherapeutical catheters. ## Methods: Sixteen nonheparinized catheters were placed in the carotid vessels of 10 patients. ten c

Scanning electron microscopic study of t
โœ Swinehart, Paul A. ;Bentley, David L. ;Kardong, Kenneth V. ๐Ÿ“‚ Article ๐Ÿ“… 1976 ๐Ÿ› Wiley (John Wiley & Sons) ๐ŸŒ English โš– 358 KB ๐Ÿ‘ 2 views

## Abstract The effects of pressure on the luminal surface of the rabbit aorta were investigated using the scanning electron microscope. The method followed was perfusion under hydrostatic pressure of a section of thoracic aorta, in vitro. The characteristic ridged pattern seen in sections fixed at

Three-dimensional structure of the Golgi
โœ Ho, Han-Chen ;Tang, Chih-Yuan ;Suarez, Susan S. ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 573 KB

In this study, the three-dimensional organization of the Golgi apparatus in mouse spermatids was elucidated by preparing testicular tissue with the osmium-DMSO-osmium method and examining it by stereo-scanning electron microscopy. The cis-most saccule was found to be a regular network of anastomotic