Three-dimensional spiral MR imaging: Application to renal multiphase contrast-enhanced angiography
โ Scribed by Michael Amann; Michael Bock; Frank Floemer; Stefan O. Schoenberg; Lothar R. Schad
- Publisher
- John Wiley and Sons
- Year
- 2002
- Tongue
- English
- Weight
- 859 KB
- Volume
- 48
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
โฆ Synopsis
A fast MR pulse sequence with spiral in-plane readout and conventional 3D partition encoding was developed for multiphase contrast-enhanced magnetic resonance angiography (CE-MRA) of the renal vasculature. Compared to a standard multiphase 3D CE-MRA with FLASH readout, an isotropic in-plane spatial resolution of 1.4 x 1.4 mm(2) over 2.0 x 1.4 mm(2) could be achieved with a temporal resolution of 6 sec. The theoretical gain of spatial resolution by using the spiral pulse sequence and the performance in the presence of turbulent flow was evaluated in phantom measurements. Multiphase 3D CE-MRA of the renal arteries was performed in five healthy volunteers using both techniques. A deblurring technique was used to correct the spiral raw data. Thereby, the off-resonance frequencies were determined by minimizing the imaginary part of the data in image space. The chosen correction algorithm was able to reduce image blurring substantially in all MRA phases. The image quality of the spiral CE-MRA pulse sequence was comparable to that of the FLASH CE-MRA with increased spatial resolution and a 25% reduced contrast-to-noise ratio. Additionally, artifacts specific to spiral MRI could be observed which had no impact on the assessment of the renal arteries.
๐ SIMILAR VOLUMES
## Abstract ## Purpose To determine the efficacy of the combined use of magnetic resonance (MR) imaging, MR cholangiography (MRC), and MR angiography (MRA) in the preoperative evaluation of gallbladder carcinoma. ## Materials and Methods During a 20โmonth period, 41 patients with proven gallblad
A composite approach for magnetic resonance (MR) angiography of the lower extremities is described. Thirty patients were studied with this approach, which combined a two-dimensional (2D) time-of-flight (TOF) technique with a 3D contrast-enhanced technique. A head/neck coil was selected for imaging m
## Abstract A single breathโhold 3D cardiac phase resolved steadyโstate free precession (SSFP) sequence was developed, allowing 3D visualization of the moving coronary arteries. A 3D stack of spirals was acquired continuously throughout the cardiac cycle, and a sliding window reconstruction was use
## Abstract A threeโdimensional (3D), ECGโtriggered, selective inversion recovery (SIR) rapid gradientโecho (RAGE) technique is proposed to obtain MR angiograms of the main renal arteries. By using the selective inversion recovery and fat saturation, the background is significantly suppressed while