The design and experiments of a graphite absorbed-dose calorimeter in the operation of quasiadiabatic mode is described which is used for measuring high dose and calibrating passive dosimeters in electron beam. KEYWORD graphite calorimeter .high dose dosimetry. radiation processing. electron beam. t
โฆ LIBER โฆ
Thin film alanine-PE dosimeter for electron beam transfer dosimetry
โ Scribed by Min Lin; Huazhi Li; Yundong Chen; Ying Cui; Zhenhong Xiao; Kesheng Chen; Juncheng Gao
- Book ID
- 108256627
- Publisher
- Elsevier Science
- Year
- 2005
- Tongue
- English
- Weight
- 230 KB
- Volume
- 73
- Category
- Article
- ISSN
- 0969-806X
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
A new graphite calorimeter for calibrati
โ
Zhang Limin; Gu jiqing; Xu Peiling; Bai Yihua; Ye Dongsheng; Wu Bin
๐
Article
๐
1993
๐
Elsevier Science
๐
English
โ 265 KB
Measurements with alanine and film dosim
โ
A. Miller; A. Kovacs; A. Wieser; D.F. Regulla
๐
Article
๐
1989
๐
Elsevier Science
โ 176 KB
Alanine and radiochromic film dosimeters were irradiated with absorbed doses from 3 to 10 kGy at a I0 MeV electron accelerator under typical radiation processing conditions. The nominal doses were measured by graphite calorimeters and the dosimeters were irradiated in graphite phantoms. The dosimete