๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Thermoanalytical Determination of Tetrazene in Primer Mixtures

โœ Scribed by G. Krien


Book ID
105355123
Publisher
John Wiley and Sons
Year
1979
Tongue
English
Weight
249 KB
Volume
4
Category
Article
ISSN
0721-3115

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

The heat of decomposition allows the quantitative determination of tetrazene in primer mixtures by DSC or DTA. The standard deviation of the method is 0.02 mg if the content in tetrazene is in the range of 0.1 mg to 1.5 mg. The confidence interval of a measurement is 0.03 mg tetrazene. This is sufficient for control measurements in view of the large variations introduced during sampling of tetrazene in small amounts of primer. The low weight required by the method (2 mg or more) enables the determination of tetrazene in friction compositions of a detonator or in percussion caps. This is important when malfunctions have to be analyzed.