Thermic effects in the “vestibule” during laser stapedotomy with pulsed laser systems
✍ Scribed by Jovanovic, S.; Schönfeld, U.; Fischer, R.; Döring, M.; Prapavat, V.; Müller, G.; Scherer, H.
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 253 KB
- Volume
- 23
- Category
- Article
- ISSN
- 0196-8092
No coin nor oath required. For personal study only.
✦ Synopsis
Background and Objective
: Apart from the ablation properties at the stapes footplate, the degree of thermic loading in the inner ear is important in determining the suitability of pulsed lasers for stapedotomy. The aim of the study is to compare the thermic effects in the vestibule with different pulsed laser systems. Study Design/Materials and Methods: Temperature increases and heat exchange processes in the fluid (physiological saline) were examined in a calorically and physiologically approximated cochlea model for applying the laser parameters effective in creating footplate perforations. Results: With all systems, increases in the energy density, number of pulses, and thus resultant total energy lead to higher temperatures. In the effective energy density range, the highest temperature increases achieved with the requisite number of pulses at a distance of 2 mm behind the perforation are 26°C with the Ho:YAG laser. The lowest temperature maxima are 5.5°C with the Er:YAG and <5°C with the Er:YSGG laser. The excimer laser, investigated at only one energy density, showed maximal temperatures of 10°C.
Conclusion:
The Er:YSGG and Er:YAG laser can be applied in laser stapedotomy in a relatively broad energy density range without a risk of inner ear damage by thermic loading. On the other hand, the Ho:YAG laser is not recommended for stapedotomy because of the higher energy density and pulse rate required for sufficient perforation and the resultant higher temperature increases in the perilymph. Though likewise achieving perforations with only slight temperature increases in the fluid of the cochlea model, the excimer laser does not seem appropriate for stapedotomy because of the long period of heat exposure (ca. 60 s) due to the lower ablation rate at the stapes necessitating a longer application time. Lasers Surg.
📜 SIMILAR VOLUMES
## Abstract ## Background and Objectives Carbon dioxide (CO~2~) lasers are an important part of dental treatment. Advances in laser technology have produced microsecond pulse durations and small beam sizes. The histological effects of porcine intraoral soft tissue with a range of microsecond‐pulse
## Background and objective: The solid-state, mid-infrared holmium:yag laser (2.1 microm wavelength) is a relatively new percutaneous device that has recently been evaluated in a multicenter study. because of its unique wavelength and photoacoustic effects on atherosclerotic plaques, this laser may
Pressure waves during excimer laser ablation of vascular tissue may be responsible for complications of coronary excimer laser angioplasty. In this experimental study, pressure waves were measured during excimer laser irradiation in blood and contrast media using a polyvinilidenefluoride hydrophone.
## Abstract ## Background and Objectives The objective of this study was to compare the efficacy and safety of cryogen spray cooled laser treatment (CSC‐LT) at wavelengths of 585 nm vs. 595 nm for port wine stain (PWS) birthmarks in a large series of patients. ## Study Design/Materials and Method