𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Thermal performance of multi-stage flash distillation plants in Saudi Arabia

✍ Scribed by Osman A. Hamed; Mohammad A.K. Al-Sofi; Monazir Imam; Ghulam M. Mustafa; Khalid Ba Mardouf; Hamad Al-Washmi


Book ID
104112603
Publisher
Elsevier Science
Year
2000
Tongue
English
Weight
597 KB
Volume
128
Category
Article
ISSN
0011-9164

No coin nor oath required. For personal study only.

✦ Synopsis


The Saline Water Conversion Corporation (SWCC) of Saudi Arabia is currently producing around 16% of the total worldwide capacity of desalted water [1]. The majority of SWCC desalination plants employs the multistage flash (MSF) distillation process which produce 94% of SWCC's total desalinated water. SWCC various MSF distillers are characterized by a wide range of operating and design conditions, The capacity of operating distillers ranges between 2.5 to 7.5 migd. Some large distillers of rated capacity up to 10 migd are under construction in Shoibah and Yanbu. The number of stages of these distillers varies between 16 and 34, while the operating top brine temperature varies between 90 Β° C and 115 Β° C. Design and operating parameters of various SWCC MSF distillers have been collected and effectively utilized to simulate and analyze the thermal performance of these distillers. The thermal performance of each distiller is quantitatively assessed using a computer program which is based on the first and the second law of thermodynamics. A comparative study on energy and exergy analyses is conducted for different MSF plants. This paper also presents a comprehensive micro-thermal analysis to identify the potential for improving plant efficiency. The exergy losses due to irreversibility in different subsystems of each MSF distiller are evaluated. Exergy destruction in the brine heater, heat recovery and heat rejection stages and friction in liquid paths are determined. The impact of different design and operating parameters such as top brine temperature and number of stages on the thermal performance of the MSF system is evaluated.


πŸ“œ SIMILAR VOLUMES


The eilat 1,000,000 GPD multi-stage flas
✍ N. Zuckerman πŸ“‚ Article πŸ“… 1969 πŸ› Elsevier Science 🌐 English βš– 585 KB

The paper describes operation of the Eilat plant in its third year. Operating parameters were kept near the values determined by previously described tests. Remarkably good results were obtained, the plant's yearly availability factor being 95x, yearly load factor being 100.4% and output factor 105.

The effect of tubeside maldistribution o
✍ T.J. Rabas πŸ“‚ Article πŸ“… 1985 πŸ› Elsevier Science 🌐 English βš– 497 KB

Previous studies have demonstrated that tubeside maldistribution can adversely affect the thermal performance of some heat exchangers. Therefore, a study was conducted to determine the effect of tubeside maldistribution on the thermal performance of the condensers used in multistage flash (MSF) dist

Comparative study of two anti-scale agen
✍ S.A. Al-Saleh; A.R. Khan πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 694 KB

The performance of MSF distiller depends on scale formation inside the condenser tubes since scale impairs heat transfer and adversely affects the production of the main utility. In the past three decades a great deal of research activity has focus& on the development and testing of anti-scale agent