Thermal-hydraulic simulation of helium expulsion from a cable-in-conduit conductor
β Scribed by Luongo, C.A.; Loyd, R.J.; Chen, F.K.; Peck, S.D.
- Book ID
- 114549970
- Publisher
- IEEE
- Year
- 1989
- Tongue
- English
- Weight
- 669 KB
- Volume
- 25
- Category
- Article
- ISSN
- 0018-9464
- DOI
- 10.1109/20.92602
No coin nor oath required. For personal study only.
π SIMILAR VOLUMES
In the design of forced flow cooling systems of large superconducting magnets for plasma confinement in future fusion reactor, the time needed, after a heat pulse (caused by magnetic field variations), for the cable to be recooled at the initial fluid temperature is an important design parameter. Th
We have developed numerical code for stability simulation of a cable-in-conduit conductor (CICC), POCHI, resulting in improved accuracy in stability simulation. However, there still remains some degree of error in evaluation for removing heat from the strand to the coolant because of limitations of