## Abstract The physiological noise in the resting brain, which arises from fluctuations in metabolic‐linked brain physiology and subtle brain pulsations, was investigated in six healthy volunteers using oxygenation‐sensitive dual‐echo spiral MRI at 3.0 T. In contrast to the system and thermal nois
Theoretical noise model for oxygenation-sensitive magnetic resonance imaging
✍ Scribed by Gaohong Wu; Shi-Jiang Li
- Book ID
- 102955024
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 923 KB
- Volume
- 53
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Contrast‐to‐noise ratio (CNR) in blood oxygenation level‐dependent (BOLD) based functional MRI (fMRI) studies is a fundamental parameter to determine statistical significance and therefore to map functional activation in the brain. The CNR is defined here as BOLD contrast with respect to temporal fluctuation. In this study, a theoretical noise model based on oxygenation‐sensitive MRI signal formation is proposed. No matter what the noise sources may be in the signal acquired by a gradient‐echo echo‐planar imaging pulse sequence, there are only three noise elements: apparent spin density fluctuations, S~0~(t); transverse relaxation rate fluctuations, R(t); and thermal noise, n(t). The noise contributions from S~0~(t), R(t), and n(t) to voxel time course fluctuations were evaluated as a function of echo time (TE) at 3 T. Both noise contributions caused by S~0~(t) and R(t) are significantly larger than that of thermal noise when TE = 30 ms. In addition, the fluctuations between S~0~(t) and R(t) are cross‐correlated and become a noise factor that is large enough and cannot be ignored. The experimentally measured TE dependences of noise, temporal signal‐to‐noise ratio, and BOLD CNR in finger‐tapping activation regions were consistent with the proposed model. Furthermore, the proposed theoretical models not only unified previously proposed BOLD CNR models, but also provided mechanisms for interpreting apparent controversies and limitations that exist in the literature. Magn Reson Med 53:1046–1054, 2005. © 2005 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Functional magnetic resonance imaging exploits deoxygenated blood as an endogeneous source for contrast in assessing local changes in tissue perfusion. Intrinsic changes in myocardial signal intensity were measured during dipyridamole induced coronary vasodilatation with __T__~2~\*‐weig
## Abstract Noise properties, the signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), and signal responses were compared during functional activation of the human brain at 1.5 and 3.0 T. At the higher field spiral gradient‐echo (GRE) brain images revealed an average gain in SNR of 1.7 in fu