Theoretical basis for sodium and potassium MRI of the human heart at 1.5 T

✍ Scribed by Todd B. Parish; David S. Fieno; Steven W. Fitzgerald; Robert M. Judd


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
860 KB
Volume
38
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Knowledge of the extent and location of viable tissue is important to clinical diagnosis. In principle, sodium (^23^Na) and potassium (^39^K) MRI could noninvasively provide information about tissue viability. In practice, imaging of these nuclei is difficult because, compared with water protons (^1^H), ^23^Na and ^39^K have lower MR sensitivities (9.2 and 0.051%, respectively), and lower in vivo concentrations (ca. 1000‐fold). On the other hand, the relatively short T~1~ relaxation times of ^23^Na and ^39^K (ca. 30 and 10 ms, respectively) suggest that optimized imaging pulse sequences may in part alleviate the weak signal of these nuclei. In this study, numerical simulations of high‐speed imaging sequences were developed and used to maximize ^23^Na and ^39^K image signal‐to‐noise ratio (SNR) per unit time within the constraints of existing gradient hardware. The simulation demonstrated that decreasing receiver bandwidth at the expense of echo time (TE) results in a substantial increase in ^23^Na and ^39^K image SNR/time despite the short T~2~ and T~2~* of these nuclei. Referenced to the available ^1^H signal on existing 1.5 T scanners, the simulation suggested that it should be possible to acquire three‐dimensional ^23^Na images of the human heart with 7 × 7 × 7 mm resolution and ^39^K images with 26 × 26 × 26 mm resolution in 30 min. Experimentally in humans at 1.5 T, three‐dimensional ^23^Na images of the heart were acquired in 15 min with 6 × 6 × 12 mm resolution and signal‐to‐noise ratios of 11 and 7 in the left ventricular cavity and myocardium, respectively, which is very similar to the predicted result. The results demonstrate that by choosing imaging pulse sequence parameters that fully exploit the short relaxation times of ^23^Na and ^39^K, potassium MRI is improved but remains impractical, whereas sodium MRI improves to the point where ^23^Na imaging of the human heart may be clinically feasible on existing 1.5 T scanners.


📜 SIMILAR VOLUMES


Dual-frequency, dual-quadrature, birdcag
✍ Gary X. Shen; Fernando E. Boada; Keith R. Thulborn 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 862 KB

Rapid quantification of tissue metabolites in vivo by MRS or MRI can be achieved using dual-frequency RF coils with identical B1 field distributions at the observation frequencies of the metabolites and tissue water protons. Tissue sodium is used as an example for optimizing the dual-frequency, dual

The sectorial loop-gap resonator for 31P
✍ A. Jesmanowicz; W. Froncisz; Thomas M. Grist; James S. Hyde 📂 Article 📅 1986 🏛 John Wiley and Sons 🌐 English ⚖ 751 KB

A new type of loop-gap resonator, which because of its topology is called a "sectorial resonator," is described in considerable analytical detail. It was used for 31P NMR of the livers of two human adult normal volunteers. An effective strategy for suppression of signals from surface tissue was deve