A model has been developed to predict average void-fractions in horizontal and vertical two-phase flow based on a single flow parameter K and the slip velocity. The model is based on the assumptions that the radial distributions of liquid velocity and void-fraction can be represented by parabolic-ty
The turbine meter applied to void fraction determination in two-phase flow
โ Scribed by P.A. Mark; M.W. Johnson; J.L. Sproston; B.C. Millington
- Publisher
- Elsevier Science
- Year
- 1990
- Tongue
- English
- Weight
- 471 KB
- Volume
- 1
- Category
- Article
- ISSN
- 0955-5986
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
published the paper "A model to predict void-fraction in two-phase flow"[ I]. This model is based on a rather sophisticated assumption of parabolic void-fraction and liquid velocity profiles. Although it was shown121, 131 that the liauid velocitv orofde is less flat in
This paper presents an approach to determine the void fraction and the drift velocity in a two-phase flow with a boiling solar collector using easily obtained experimental data. The solar collector operates in a thermal siphon circuit, where the working fluid absorbs solar radiation mostly while boi