The third level trigger and output event unit of the UA1 data-acquisition system
โ Scribed by S. Cittolin; M. Demoulin; A. Fucci; W. Haynes; B. Martin; J.P. Porte; P. Sphicas
- Publisher
- Elsevier Science
- Year
- 1989
- Tongue
- English
- Weight
- 550 KB
- Volume
- 57
- Category
- Article
- ISSN
- 0010-4655
No coin nor oath required. For personal study only.
โฆ Synopsis
The upgraded UA1 experiment utilizes twelve 3081/E emulators for its third-level trigger system. The system is interfaced to VME, and is controlled by 68000 microprocessor VME boards on the input and output. The output controller communicates with an IBM 9375 mainframe via the CERN-IBM developed VICI interface. The events selected by the emulators are output on IBM-3480 cassettes. The user interface to this system is based on a series of Macintosh personal computers connected to the VME bus. These Macs are also used for developing software for the emulators and for monitoring the entire system. The same configuration has also been used for offline event reconstruction. A description of the system, together with details of both the online and offline modes of operation and an evaluation of its performance are presented.
๐ SIMILAR VOLUMES
A simple method of interfacing clinical and research laboratory equipment with a microcomputer is described. A four-channel buffer system has been constructed which stores data generated from laboratory instruments and then transmits the data directly to a microcomputer. The system is highly flexibl