The separation of dimethylarsinic acid, methylarsonous acid, methylarsonic acid, arsenate and dimethylarsinous acid on the Hamilton PRP-X100 anion-exchange column
✍ Scribed by Jürgen Gailer; Sean Madden; William R. Cullen; M. Bonner Denton
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 71 KB
- Volume
- 13
- Category
- Article
- ISSN
- 0268-2605
No coin nor oath required. For personal study only.
✦ Synopsis
In order to separate the potential arsenite metabolites methylarsonous acid and dimethylarsinous acid from arsenite, arsenate, methylarsonic acid and dimethylarsinic acid, the pHdependent retention behaviour of all six arsenic compounds was studied on a Hamilton PRP-X100 anion-exchange column with 30 mM phosphate buffers (pH 5, 6, 7, 8 and 9) containing 20% (v/v) methanol as mobile phase and employing an inductively coupled plasma atomic emission spectrometer (ICP-AES) as the arsenic-specific detector. Baseline separation of dimethylarsinic acid, methylarsonous acid, methylarsonic acid, arsenate and dimethylarsinous acid was achieved with a 30 mmol dm À3 phosphate buffer (pH 5)-methanol mixture (80:20, v/v) in 25 min. Arsenite is not baselineseparated from dimethylarsinic acid under these conditions.