๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

The pyramidal-mirror detector for scanning laser acoustic microscopy

โœ Scribed by L. R. Sahagun; F. Mendoza-Santoyo; G. Wade; S. Isakson


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
375 KB
Volume
10
Category
Article
ISSN
0899-9457

No coin nor oath required. For personal study only.

โœฆ Synopsis


The pyramidal-mirror detector has important advantages over the knife-edge detector currently in use in scanning laser acoustic microscopy. A key element of this new detector is a foursided pyramid with mirrored surfaces. In the operation of the microscope, the zero-order component of the light of the scanning laser beam that has been reflected from the microscope's coverslip is centered on the tip of the pyramid. Thus, each mirror face reflects one fourth of the light in this component. Making use of an arrangement of four photodetectors, one for each of the four faces of the pyramidal mirror, the light reflected from each face goes to a different photodetector and is processed separately from the light reflected from the other faces. This detector has an almost isotropic transfer function with no negative responses and fourfold symmetry around a null point in the center which coincides with the zero-frequency point in the spatial spectrum. This property makes it possible to detect spatial frequencies in all directions simultaneously with almost equal sensitivity. Oblique insonification, required for best operation with the knife-edge detector because of its region of negative response, is not preferred in the pyramidal-mirror detector and double side-band detection can be employed. Since there is no requirement that a negative response region be avoided, the spatial spectrum of this detector can be more than twice that of the knife-edge detector. The tighter the focusing of the scanning laser beam onto the coverslip, the higher the spatial frequencies detectable in the object. In fact, if the coverslip occupies a position in the very-near field of the object, evanescentwave detection is possible. Low-frequency, highly penetrable ultrasound can be used and at the same time high spatial frequencies can be detected for obtaining high resolution.


๐Ÿ“œ SIMILAR VOLUMES


Detection systems for scanning laser tom
โœ A. Meyyappan; S. Isakson; F. Mendoza-Santoyo; R. A. Duarte; L. R. Sahagun; G. Wa ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 485 KB

A new microscope, called the scanning laser tomoholographic acoustic microscope, will employ three insonifying transducers to obtain holographic projections from three different directions for use in reconstructing tomograms of microscopic objects. To do this, the detection system should detect with

Confocal laser scanning microscopy (CLSM
โœ Hanthamrongwit, M. ;Grant, M. H. ;Wilkinson, R. ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 414 KB

This study uses confocal laser scanning microscopy (CLSM) to assess the microstructure of collagen sponges providing an accurate quantification of porosity under conditions similar to those experienced by cells growing on the sponges during culture. CLSM offers several advantages over scanning elect

Confocal Scanning Laser Microscopy as a
โœ A. Thill; M. Wagner; J.Y. Bottero ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 85 KB

Several assumptions are made when confocal scanning laser microscopy is used for the determination of the fractal dimension of aggregates. The purpose of this study is to experimentally show that one of these assumptions, which concerns the relation existing between the structure of an aggregate and

Confocal laser-scanning microscopy for d
โœ Hanthamrongwit, M. ;Wilkinson, R. ;Osborne, C. ;Reid, W. H. ;Grant, M. H. ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 874 KB

The development of artificial skin substitutes based on cultured cells and biomaterials such as collagen requires an understanding of cellular interactions with the substrate. In this study, human keratinocytes were cultured on the surface of collagen sponges, and confocal laser-scanning microscopy