## Abstract Subjective and physiologic effects of 33% inhaled Xe were measured with ^15^Oβwater positron emission tomography (PET) in 3 subjects at rest and during visual stimulation. The procedure was well tolerated. Robust functional activations of the visual cortex were obtained after xenon (Xe)
The pharmacokinetics of hyperpolarized xenon: Implications for cerebral MRI
β Scribed by Charles C. Martin; Robert F. Williams; Jia-Hong Gao; Lisa D. H. Nickerson; Jinhu Xiong; Peter T. Fox
- Book ID
- 102905554
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 824 KB
- Volume
- 7
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
In this work, a compartmental model to predict the concentration of hyperpolarized xenon (Xe) in the brain is developed based on the well established kinetics of Xe and estimated T1 values for the compartments. For the gaseous compartments, T1 was set to 12 seconds. For the tissue compartments, T1 was set to 6 seconds. Three gas delivery techniques were modeled: hyperventilation followed by breathβhold, continual breathing, and hyperventilation followed by continual breathing. Based on Xe CT, it is estimated that the maximum concentration of Xe that could be breathed is 80%. Based on this value and the estimated maximum polarization of 50%, the peak gray matter concentration of hyperpolarized Xe is calculated to be .036 mM. This leads to an estimated signalβtoβnoise ratio (SNR), at 2 T, for hyperpolarized Xe that is a factor of 50 lower than the SNR for proton MRI. The peak concentration of hyperpolarized Xe was also calculated over a wide range of gas and tissue T1 values. This model also predicts that the arterial blood will have a concentration of hyperpolarized Xe that is 10 times greater than the concentration in gray matter. An interactive version of the model can be found on the World Wide Web at http://ric.uthscsa.edu/staff/charlesmartinphd.html.
π SIMILAR VOLUMES
## Abstract ## Purpose To apply a continuous flowβtype hyperpolarizing (CFβHP) system to lung imaging and investigate the feasibility of hyperpolarized ^129^Xe MRI at a low xenon concentration. ## Materials and Methods Under two conditions where a 3% or 70% xenon gas mixture was constantly suppl
In this contribution we report new approaches to the MRI of materials using continuously produced laser-polarized 129 Xe gas. This leads to vastly improved sensitivity and makes new kinds of information available. The hyperpolarized xenon is produced in a continuous flow system that conveniently del
## Abstract We used the dual capability of hyperpolarized ^129^Xe for spectroscopy and imaging to develop new measures of xenon diffusing capacity in the rat lung that (analogously to the diffusing capacity of carbon monoxide or __D__~__LCO__~) are calculated as a product of total lung volume and g