Axial conduction is a major source of inefficiency in a compact counterflow heat exchanger. Any attempt to reduce axial conduction by using material of low thermal conductivity for the separating wall results in increased resistance to lateral heat flow, thereby reducing the overall thermal efficien
The performance of electrogasdynamic expanders with slightly conducting walls
โ Scribed by D. Wadlow; P.J. Musgrove
- Publisher
- Elsevier Science
- Year
- 1976
- Weight
- 886 KB
- Volume
- 15
- Category
- Article
- ISSN
- 0013-7480
No coin nor oath required. For personal study only.
โฆ Synopsis
AlOft't--In electrogasdynamic (EGD) devices the radial movement of charge carders to insulating duct walls can produce high parasitic electric fields and greatly degrade the overall performance. In principle these parasitic fields may be reduced by constructing the EGD ducts from slightly conducting materials, but there is then a power loss due to current flow through the wall. This paper examines the effect of particle deposition velocity, wall resistivity, load resistance and aspect ratio, as well as ttuid friction and gas density, on this resistive wall power loss and on the overall performance of EGD devices. Given suitable and realistic values of the relevant parameters, isentropic efficiencies in excess of 85 per cent are predicted at pressures of the order 10-40 atmospheres.
Electrogasdynamics
Energy conversion Charged aerosols Direct conversion Corona discharge Particle deposition