✦ Synopsis


Burnett-type apparatus for the determination of the compression factor and virial coefficients of gases has been constructed and calibrated by helium. The apparatus operates from near room temperature to T s 473 K and pressures up to 60 MPa. To evaluate the capability of the apparatus, Burnett expansion series were performed with 1,1,1,2-Ž . tetrafluoroethane HFC-134a at T s 393 K. The new measured data for HFC-227ea at the temperatures 393 K and 423 K and pressures ranging from 0.2 MPa to 50 MPa are presented. A finite density virial expansion was employed to derive compression factors and second virial coefficients from the data obtained. The experimental densities and second virial coefficients are compared with values calculated by the internationally agreed equations of state of helium and HFC-134a. The experimental uncertainty of the measurements is estimated to be . "0.0002 p in pressure and "0.005 K in temperature. The uncertainties involved in the measurement of the density and the virial coefficients are discussed.


📜 SIMILAR VOLUMES


Measurements of the (T, p, p) behaviour
✍ J. Klomfar; J. Hrubý; O. Šifner 📂 Article 📅 1994 🏛 Elsevier Science 🌐 English ⚖ 176 KB

Measurements of the ( \(T, p, \rho\) ) behaviour for \(1,1,1,2,3,3,3\)-heptafluoropropane (R227) were performed with a constant-volume cell at temperatures from \(205 \mathrm{~K}\) to \(315 \mathrm{~K}\) and pressures up to \(52 \mathrm{MPa}\). The uncertainties for pressure \(p\), temperature \(T\)

(p, ρ, T) measurements of (ammonia 
✍ J. Kondo; Y. Yasukawa; M. Uematsu 📂 Article 📅 2002 🏛 Elsevier Science 🌐 English ⚖ 430 KB

Measurements of ( p, ρ, T ) for {x NH 3 + (1 -x)H 2 O} at x = (1.0000, 0.8374, 0.6005, and 0.2973) and at specified temperatures and pressures in the compressed liquid phase were carried out with a metal-bellows variable volumometer between T = 310 K and T = 400 K at pressures up to 17 MPa. The resu

( p, ρ, T) measurements of (ammonia&#xa0
✍ T Munakata; K Kasahara; M Uematsu 📂 Article 📅 2002 🏛 Elsevier Science 🌐 English ⚖ 483 KB

p, ρ, T ) measurements of (ammonia + water) in the temperature range 310 K to 400 K at pressures up to 17 MPa. I. Measurements of {xNH 3 + (1 -x)H 2 O} at x = (0.8952, 0.8041, 0.6985, 0.5052, and 0.1016)