𝔖 Bobbio Scriptorium
✦   LIBER   ✦

The measurement and effects of friction and wear in artificial hip joints

✍ Scribed by Walker, P. S. ;Salvati, E.


Publisher
John Wiley and Sons
Year
1973
Tongue
English
Weight
768 KB
Volume
7
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The two systems for artificial hip joints in use at present are metal‐on‐metal and metal‐on‐plastic. There are many variables affecting friction and wear, which include diameter, sphericity, relative geometry of the components, and surface roughness. Tests in a simulating machine incorporated cyclic load and motion. Frictional torque of metal‐on‐plastic joints increased with diameter; Charnley 22 mm diameter producing lowest friction. For metal‐on‐metal the contact situation produced variable results, but friction was higher than for the plastic joints. Reciprocating friction machine tests suggested that high molecular weight polyethylene and AP4 polyester gave low friction and wear. Vitallium gave at least three times the friction of the plastic using γ‐globulin solution as lubricant; but wear appeared to be much less.


📜 SIMILAR VOLUMES


Friction-Induced Vibration of Artificial
✍ Cornelius Weiss; Arne Hothan; Michael Morlock; Norbert Hoffmann 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 256 KB

A hip replacement system is analysed with respect to its susceptibility to friction induced vibrations under laboratory conditions and in a pseudo-in vivo setup. The method of complex eigenvalue extraction within the framework of finite-element modelling and analysis is used to identify the geometri

Adjustment of wear particle size distrib
✍ B. Stamm; B. Küzün; O. Filipov; S. Reuter; I. Erdmann; F. Deuerler; D. Krix; K. 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 143 KB

## Abstract The term DLC (diamond‐like carbon) describes a whole class of different biocompatible materials based on amorphous carbon. One possible application for DLC is the coating of artificial hip joints to increase their life expectancy. The life expectancy of artificial hip joints is limited

Biological response to wear debris gener
✍ Howling, G. I. ;Sakoda, H. ;Antonarulrajah, A. ;Marrs, H. ;Stewart, T. D. ;Apple 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 280 KB

## Abstract UHMWPE wear particles have been implicated in osteolysis, implant loosening, and long‐term failure of total hip arthroplasties __in vivo__. This study examined four carbon‐based composite materials as alternatives for UHMWPE in joint bearings. These materials were HMU‐CVD, SMS‐CVD, P25‐

Electromagnetic effects on the friction
✍ B. Bhushan; S. Ge 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 410 KB

## Abstract This paper presents the state‐of‐the‐art of recent investigations on the friction and wear behavior of some solid interfaces in a magnetic field or electric current environment. The tribometers used for study of electromagnetic effect on friction and wear are introduced. The experimenta

Matrix metalloproteinases and tissue inh
✍ Takei, Isao ;Takagi, Michiaki ;Santavirta, Seppo ;Ida, Hideo ;Hamasaki, Makoto ; 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 313 KB 👁 1 views

The pseudojoint cavity formed in patients undergoing total hip arthroplasty (THA) is later remodeled to synovial membrane-like tissue, which produces pseudosynovial fluid. This pseudosynovium also is an important source of matrix metalloproteinases (MMPs). As it is widely speculated that synovial fl