In the present study, the theoretical and experimental results of the second law analysis on the heat transfer and flow of a horizontal concentric tube heat exchanger are presented. The experiments setup are designed and constructed for the measured data. Hot water and cold water are used as working
The influence of the injectors with swirling flow generating on the heat transfer in the concentric heat exchanger
✍ Scribed by Gülşah Çakmak; Cengiz Yıldız
- Publisher
- Elsevier Science
- Year
- 2007
- Tongue
- English
- Weight
- 660 KB
- Volume
- 34
- Category
- Article
- ISSN
- 0735-1933
No coin nor oath required. For personal study only.
✦ Synopsis
In this paper, undertaken to enhance heat transfer rates, swirling motion was imposed on the hot air by placing injectors with various diameters and numbers in triangle line rows on the entrance section of the inner pipe of the concentric heat exchanger. With this aim various the injectors were prepared to test in the experiments. These elements can be placed and removed easily on the entrance section of the inner pipe. The experiments were carried out for counter current flow models of the fluids at different Reynolds numbers. The heat transfer rates increased with decreasing diameter and with increasing number of the injectors used in the experiments.
The results showed that up to 93% enhancements could be accomplished in heat transfer rates with this kind of swirl generators compared to heat exchanger without these elements. In the end of the study, the results showed that a rather smaller size but the same capacity heat exchanger could be proposed by using these elements imposing swirling to the fluid flowing through inner pipe.
📜 SIMILAR VOLUMES
The flow in the transition region of the wake behind a circular cylinder transverse to the flow is discussed in the light of recent detailed hot-wire studies, and it is found that these studies present a completely consistent qualitative explanation of the heat transfer measurements of FAND and CHEN
a spray column Temperature profiles of dispersed kerosene and water were measured in I heat exchanger,. 15 cm. in diameter and 160 cm. long. Dispersed packing of drops and narrow temperoture ranges were used. The flow rates used were 0 to 50 liters/min. of water ond 5 to 40 liters/min. of kerosene.