## Abstract The flow and polymerization characteristics of poly(methylmethacrylate) (PMMA) bone cement can be changed by manipulating the temperature of the bone cement components or the environment that they are prepared in. To quantify the effects of the initial component temperature (__T__~ic~)
The influence of temperature and specimen size on the flexural properties of pmma bone cement
β Scribed by Brown, S. A. ;Bargar, W. L.
- Publisher
- John Wiley and Sons
- Year
- 1984
- Tongue
- English
- Weight
- 872 KB
- Volume
- 18
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
A three-stage investigation was undertaken to examine the influence of specimen size and polymerization environment on the flexural properties of PMMA. In the first stage, specimens were cut from large pieces of commercially cast acrylic (lucite) and self-curing dental acrylic. The material properties of the cast acrylic as calculated from the results of flexural testing were not influenced by specimen size in the range of 1 X 10 X 30 to 3 X 10 X 60 mm, whereas 1-mm thick dental cement specimens had 12% (p less than 0.001) higher stress and 24% (p less than 0.001) higher strain to failure than 3-mm specimens cut from the same sample. In the second stage, self-curing dental cement and Simplex P bone cement were molded in different thicknesses. These experiments demonstrated that molding thin 1.6-mm specimens resulted in increases of 14% (p less than 0.001) in stress and 30% (p less than 0.001) in strain to failure as compared with 3.2-mm specimens, which were greater differences than those due to the specimen thickness effects alone. In the third stage, temperatures of cement were monitored during polymerization, and cements were molded at different temperatures. These results demonstrated that thicker cement samples reached higher temperatures and that cement samples polymerized at lower temperatures (21 versus 37 degrees C) had 12% (p less than 0.001) greater stress and 105% (p less than 0.001) greater strain to failure.
π SIMILAR VOLUMES
## Abstract The effect of varying the initial temperature of the components of poly(methyl methacrylate) (PMMA) bone cement has been investigated. Electron paramagnetic resonance (EPR) spectroscopy was used to monitor free radical decay during the curing of the cement. Samples cured in saline at 37
## Abstract In all but one of the acrylic bone cement brands used in cemented arthroplasties, __N__,__N__βdimethylβ4βtoluidine (DMPT) serves as the activator of the polymerization reaction. However, many concerns have been raised about this activator, all related to its toxicity. Thus, various work
It has been shown that preheating the femoral stem prior to insertion minimizes interfacial porosity at the stem-cement interface. In this study, the effects of methylmethacrylate monomer temperature prior to mixing on the properties of stem-cement interface and cement polymerization were evaluated
Predictions of graphite strength under tensile and bending loads using fracture mechanics have been compared with experimental data and the currently used Weibull method. The methods are comparable for similar specimens but Weibull's method fails to predict the observed effects for large specimen si