We propose to use MICROMEGAS, a new gaseous detector, in the tracking system of the COMPASS experiment. COMPASS will make use of the high energy (200 GeV) and high intensity (10% -1) muon beam at CERN. MICROMEGAS chambers are good candidates for the tracking of leptons and hadrons in areas of ~ 0.2
β¦ LIBER β¦
The gaseous microstrip detector Micromegas for the high-luminosity COMPASS experiment at CERN
β Scribed by C. Bernet; P. Abbon; J. Ball; Y. Bedfer; E. Delagnes; A. Giganon; F. Kunne; J.-M. Le Goff; A. Magnon; C. Marchand; D. Neyret; S. Panebianco; H. Pereira; S. Platchkov; S. Procureur; P. Rebourgeard; G. Tarte; D. Thers
- Book ID
- 108218922
- Publisher
- Elsevier Science
- Year
- 2005
- Tongue
- English
- Weight
- 475 KB
- Volume
- 536
- Category
- Article
- ISSN
- 0168-9002
No coin nor oath required. For personal study only.
π SIMILAR VOLUMES
The micromegas detector as a high flux a
β
D. Thers; Ph. Abbon; J. Ball; R. Durand; J.C. Faivre; A. Giganon; J.M. Le Goff;
π
Article
π
1999
π
Elsevier Science
π
English
β 208 KB
Cryogenic Silicon Detectors for the COMP
β
K. Bicker; H. Angerer; E. Burtin; J.M. Friedrich; F. Gautheron; S. GrabmΓΌller; N
π
Article
π
2011
π
Elsevier Science
π
English
β 205 KB
The silicon multiplicity detector for th
β
B Alessandro; S BeolΓ©; G Bonazzola; W DaΜ§browski; P Deremigis; P Giubellino; P G
π
Article
π
2002
π
Elsevier Science
π
English
β 944 KB
A fast, high-granularity silicon multipl
β
B. Alessandro; M. Alexeline; C. Baglin; V. Bisi; G. Bonazzola; P. Bonello; A. Bu
π
Article
π
1995
π
Elsevier Science
π
English
β 449 KB
A streamer tube detector for operation a
β
J.M Bennet; M Carroll; E.L Cawley; M Dodgson; J.R Fry; E Gabathuler; R Gamet; P
π
Article
π
1996
π
Elsevier Science
π
English
β 527 KB
The Detector for the Kaon Rare Decays Ex
β
Massimo Lenti
π
Article
π
2011
π
Elsevier Science
π
English
β 158 KB
The NA62 experiment at CERN is aimed at a 10% measurement of BR K + β Ο + Ξ½ Ξ½ . The beam line used, the detectors and the experimental strategy will be described.