𝔖 Bobbio Scriptorium
✦   LIBER   ✦

The effects of machined workpiece surface integrity on the fatigue life of γ-titanium aluminide

✍ Scribed by A.R.C Sharman; D.K Aspinwall; R.C Dewes; D Clifton; P Bowen


Publisher
Elsevier Science
Year
2001
Tongue
English
Weight
242 KB
Volume
41
Category
Article
ISSN
0890-6955

No coin nor oath required. For personal study only.

✦ Synopsis


Tension-tension tests on turned, electro-chemical machined (ECM) and electro-discharge textured (EDT) specimens made from Ti-45Al-2Nb-2Mn+0.8 vol% TiB 2 alloy, showed the turned specimens to have a higher fatigue strength ෂ475 MPa. It is likely that this was due to the presence of highly compressive surface residual stresses caused by the turning operation.


📜 SIMILAR VOLUMES


The effect of matrix microstructure and
✍ S.L. Kampe; J. Christodoulou; C.R. Feng; L. Christodoulou; D.J. Michel 📂 Article 📅 1998 🏛 Elsevier Science 🌐 English ⚖ 1016 KB

AbstractÐThe in¯uences of composite matrix microstructure, reinforcement shape, and processing methodology have been evaluated for a series of near-gamma (Ti 3 Al + TiAl) titanium aluminide matrix composites evaluated in tension and tensile-creep at 8008C. Speci®cally, heat treatments were imposed t