A total of 44 rat saphenous nerves were isolated. A pair of stimulating electrodes was positioned distally (at the ankle) to evoke a compound action potential (CAP) which was recorded proximally (in the thigh) through another pair of electrodes. Bone cement was then placed adjacent to the nerve midw
The effects of implanted ionomeric and acrylic bone cements on peripheral nerve function
โ Scribed by A. R. Loescher; P. P. Robinson; I. M. Brook
- Publisher
- Springer
- Year
- 1994
- Tongue
- English
- Weight
- 375 KB
- Volume
- 5
- Category
- Article
- ISSN
- 0957-4530
No coin nor oath required. For personal study only.
โฆ Synopsis
The effects of two experimental ionomeric and one commercial acrylic bone cement and set ionomeric microimplant bone substitute (Ionogran ยฎ) on peripheral nerve conduction, 1 and 3 weeks after implantation, have been compared. In 44 experiments the rat saphenous nerve was exposed midway between the ankle and thigh and bone cement placed into a pocket created in the connective tissue adjacent to the nerve. In terminal experiments, 1 and 3 weeks later, stimulating electrodes were placed on the saphenous nerve at the ankle, and the amplitude and conduction velocity of the compound action potential (CAP) evoked was recorded through another pair of electrodes positioned on the nerve proximal to the implant, in the thigh. One week after placing an ionomeric bone cement (HVA or V-4), no neural activity could be recorded. Three weeks, after HVA implantation apparently normal CAPs were recorded indicating a recovery from a temporary nerve conduction block, but 3 weeks after V-4 implantation only small CAPs were recorded and these could be attributed to axonal regeneration. After implantation of acrylic bone cement, small CAPs were recorded after 1 week, and within 3 weeks nerve conduction appeared to have completely recovered. Three weeks after placing set ionomeric microimplant particles the amplitude and conduction velocity of the CAP was similar to the controls.
๐ SIMILAR VOLUMES
## Abstract There is a very delicate relation between the amounts of all the ingredients present in the cement composition and the properties of the product. In this study, homogeneous poly(methyl methacrylate) (PMMA) microspheres were prepared by suspension polymerization technique, and used in ce
Changes in the mechanical properties of the rat femur caused by intramedullary application of bone cement were studied. In one group of animals reaming of the medullary cavity was performed, and bone cement was injected. In a control group only reaming was performed. At various intervals from day 0