The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis
✍ Scribed by Oğuz Eraslan; Özgür İnan
- Publisher
- Springer
- Year
- 2009
- Tongue
- English
- Weight
- 373 KB
- Volume
- 14
- Category
- Article
- ISSN
- 1432-6981
No coin nor oath required. For personal study only.
📜 SIMILAR VOLUMES
## Abstract Soft tissue damage has been observed in hip joints with pathological geometries. Our primary goal was to study the relationship between morphological variations of the bony components of the hip and resultant stresses within the soft tissues of the joint during routine daily activities.
It is possible that fatigue cracks may appear in turbomachine blades which are subjected to extreme conditions during operation. Such cracks may become the cause of failure. The feasibility of considering the natural frequency as a parameter for detecting full depth cracks has been considered earlie
Plates with centraI through cracks subjected to bending is analysed taking into account the closure of ihe crack faces on the compression side. A r~ee-dimension finite element method emplo~g t~ee~~ensjon~ degenerate SOB element is used for the amdysis. The crack faces have been mode&d such that they