## Abstract Several studies reported decreased signal intensities within auditory areas for experimental designs employing continuous scanner background noise (SBN) in comparison to designs with less or no SBN. This study examined the source for this SBN‐induced masking effect of the blood oxygenat
The effect of MR scanner noise on auditory cortex activity using fMRI
✍ Scribed by Carrie J. Scarff; Joseph C. Dort; Jos J. Eggermont; Bradley G. Goodyear
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 297 KB
- Volume
- 22
- Category
- Article
- ISSN
- 1065-9471
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Auditory functional magnetic resonance imaging (fMRI) studies are limited by the presence of noise produced by echo planar imaging (EPI). The current study quantifies the effect of MR scanner noise on psychophysical measures of the perception of loudness and on measures of tonotopy, the representation of auditory frequencies within the auditory cortex. Seven normal hearing adults were examined using tones of 5 different auditory frequencies (250, 500, 1,000, 2,000, 4,000 Hz) of equal loudness. Using an imaging protocol with peak MR scanner noise at 1,460 Hz, the perception of loudness and detectable fMRI activity in response to a 1‐kHz tone was less compared to other frequencies. When the imaging protocol was changed such that peak MR scanner noise occurred at 2,080 Hz, the perception of loudness and detectable fMRI activity in response to a 2‐kHz tone was less compared to other frequencies. The reduction in the measured fMRI activity for tones near scanner frequencies may be due to an inflated scanner‐induced baseline at those frequencies. In addition, fMRI activity decreased with increasing frequency, possibly due to the upward spread of masking of low‐frequency, high‐intensity tonal stimuli or the proximity of low‐frequency core and belt areas of the auditory cortex. These results demonstrate the direct effect of scanner noise and high‐intensity tonal stimuli on measurements of auditory cortex tonotopy. Hum. Brain Mapping 22:341–349, 2004. © 2004 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract We compared two experimental designs aimed at minimizing the influence of scanner background noise (SBN) on functional MRI (fMRI) of auditory processes with one conventional fMRI design. Ten subjects listened to a series of four one‐syllable words and had to decide whether two of the wo
## Abstract MR acoustic, or sound, noise due to gradient pulsing has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as brain fMRI. Especially in brain fMRI, sound noise is one of the serious noise sources that obscur
## Abstract Several studies have shown marked differences in the neural localization of language functions in the brains of left‐handed individuals when compared with right‐handers. Previous experiments involving functional lateralization have demonstrated cerebral blood flow patterns that differ c
## Abstract ## Objective The underlying effect of serotonergic neurotransmission has been implicated in several psychiatric disorders. The inability to routinely and non‐invasively determine the integrity of the serotonergic system __in vivo__ has limited our understanding of disorders with a puta