✦ Synopsis
Abstract
A magnetization transfer (MT)‐prepared echo‐planar imaging (EPI) pulse sequence was developed to study motor cortex activation, using a finger tapping paradigm. MT weighting resulted in a reduction of both the activated area and, in the majority of activated pixels, the functional MRI signal, regardless of the correlation coefficient threshold used in generating the activation map. The magnetization transfer ratio (MTR) was higher during task activation than during rest. Because the MT effect is strongly tissue‐dependent, these results support the hypothesis that incorporation of MT into functional MRI will help to understand the origin of the functional MRI signal.
📜 SIMILAR VOLUMES
## Abstract The primarily intravascular magnetization transfer (MT)‐independent changes in functional MRI (fMRI) can be separated from MT‐dependent changes. This intravascular component is dominated by an arterial blood volume change (ΔCBV~a~) term whenever venous contributions are minimized. Stimu
## Abstract Magnetization transfer contrast has been used commonly for endogenous tissue contrast improvements in angiography, brain, body, and cardiac imaging. Both off‐resonant and on‐resonant RF pulses can be used to generate magnetization transfer based contrast. In this study, on‐resonant magn
## Abstract Functional MRI (fMRI) signal dependence on changes in blood flow velocities were analyzed for both conventional and echo‐planar (EPI) gradient‐echo pulse sequences. As the flow velocity increases, the fMRI signal increases monotonically in spoiled gradient‐echo sequences, while the fMRI
## Abstract Magnetic resonance imaging of the knee was performed in 28 patients (ages 15–72 years), using a 1.5‐T unit. Volume gradient echo (3D GRASS) acquisition with and without presaturation off‐resonance RF pulse was used to evaluate magnetization transfer (MT) effects, determined by placing r
## Abstract Magnetization transfer effects induced by repetitive saturation pulses employed in flow enhancement of signal intensity imaging sequences currently prevent quantitative, in vivo, cerebral perfusion studies. This study investigates the magnitude of these effects and introduces a post‐pro