The Effect of Inhomogeneous Sample Susceptibility on Measured Diffusion Anisotropy Using NMR Imaging

✍ Scribed by J.D. Trudeau; W.T. Dixon; J. Hawkins


Publisher
Elsevier Science
Year
1995
Tongue
English
Weight
1016 KB
Volume
108
Category
Article
ISSN
1064-1866

No coin nor oath required. For personal study only.

✦ Synopsis


Water diffusion measurements in white matter of freshly excised pig spinal cord and in parenchyma of fresh celery (excluding the fibers along the edge of the stalk) were performed using NMR at (200 \mathrm{MHz}). In white matter of pig spinal cord, the measured diffusion coefficient is anisotropic and independent of sample orientation with respect to the magnetic field. In celery parenchyma, diffusion is isotropic and independent of orientation in the magnetic field when using a diffusion sequence that gives results independent of self-induced magnetic-field gradients. However, when the standard diffusion pulse sequence that gives results dependent upon self-induced magnetic-field gradients is used, diffusion in celery appears isotropic when the stalk is oriented parallel to the magnetic field but anisotropic when oriented perpendicular. Susceptibility variations leading to anisotropic self-induced magnetic-field gradients approximately (3 \mathrm{kHz} / \mathrm{cm}) in magnitude when the celery is oriented perpendicular to the magnetic field can explain this apparent anisotropic diffusion. A study of the apparent diffusion coefficient (ADC) in celery as a function of diffusion times ranging from 8 to (22 \mathrm{~ms}) indicates that the motion is at most only slightly restricted. Therefore, although the effect is not seen in all types of samples, one must be aware that self-induced gradients may affect the ADC and may cause isotropic diffusion to appear anisotropic. In addition, NMR experiments that change diffusion-sensitizing gradient timings to study restricted diffusion change the effects of the self-induced gradients as well as the effect of barriers on the ADC, complicating interpretation. β‘²95 Academic Press, Inc.


πŸ“œ SIMILAR VOLUMES


The Use of Sample Rotation for Minimizin
✍ Nuria Esturau; Francesc SΓ‘nchez-Ferrando; JosΓ© AdriΓ‘n Gavin; Christian Roumestan πŸ“‚ Article πŸ“… 2001 πŸ› Elsevier Science 🌐 English βš– 144 KB

Undesirable temperature gradients in a NMR sample tube are usually generated by an inappropiate temperature regulation system. We have shown that such convection effects can greatly distort the measurement of translational self-diffusion coefficients. The use of sample spinning helps to minimize suc

Efficient measurement and calculation of
✍ Erik M. Akkerman πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 350 KB

The Platonic variance method produces MR diffusion anisotropy (DA) images with a minimum amount of computational effort. It can be programmed in a self-contained MR sequence, thus eliminating the need for postprocessing on a separate workstation. The method uses gradient acquisition schemes, based o

The Effect of Magnetic Field Inhomogenei
✍ U. Eliav; T. Kushnir; T. Knubovets; Y. Itzchak; G. Navon πŸ“‚ Article πŸ“… 1997 πŸ› Elsevier Science 🌐 English βš– 153 KB

The effects of magnetic fields B 0 and B 1 inhomogeneities on either by a 180Њ pulse in the middle of the creation time in techniques which are commonly used for the measurements of the standard TQF sequence (Fig. 1a) (6) or by selecting a triple-quantum-filtered (TQF) NMR spectroscopy of 23 Na in b

Measurement of the Principal Values of t
✍ S.V. Dvinskikh; I. FurΓ³ πŸ“‚ Article πŸ“… 2001 πŸ› Elsevier Science 🌐 English βš– 86 KB

NMR methods (S. V. Dvinskikh et al., J. Magn. Reson. 142, 102-110 (2000) and S. V. Dvinskikh and I. FurΓ³, J. Magn. Reson. 144, 142-149 (2000)) that combine PGSE with dipolar decoupling are extended to polycrystalline solids and unoriented liquid crystals. Decoupling suppresses dipolar dephasing not