𝔖 Bobbio Scriptorium
✦   LIBER   ✦

The effect of high performance gradients on fast gradient echo imaging

✍ Scribed by Scott B. Reeder; Elliot R. McVeigh


Publisher
John Wiley and Sons
Year
1994
Tongue
English
Weight
777 KB
Volume
32
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The effect of gradient system performance on segmented k‐space gradient echo imaging is presented. Three cases were investigated. First, an ideal system that has infinite slew rates and unlimited maximum gradient strengths was considered. Second, a “high speed” imaging system (2.3 (G/cm), 23 (G/cm)/ms) was considered. These two cases were compared with a “conventional” imaging system (1(G/cm), 1.67 (G/cm)/ms). It was found that substantial increases in SNR can be achieved (≈︁ 45%) by using high speed versus a conventional gradient system, for a TR of 6 ms. For trapezoidal gradient waveforms, there exists an optimum maximum gradient strength for a given slew rate, and any increase in gradient strength above this optimum will not be utilized by an optimized sequence. These studies have shown that increasing TR without decreasing the bandwidth is not a good way to increase SNR for constant scan time.


📜 SIMILAR VOLUMES


Inflow effect correction in fast gradien
✍ Marko K. Ivancevic; Ivan Zimine; Xavier Montet; Jean-Noel Hyacinthe; François La 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 256 KB

## Abstract The purposes of this study were to assess the extent of the inflow effect on signal intensity (SI) for fast gradient‐recalled‐echo (GRE) sequences used to observe first‐pass perfusion, and to develop and validate a correction method for this effect. A phantom experiment with a flow appa

Comparison of three-dimensional fast spi
✍ Petra Schmalbrock 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 669 KB

T2-weighted high-resolution gradient and fast spin echo sequences are widely used as an alternative or adjunct to contrast-enhanced T1-weighted temporal bone imaging. However, to date no systematic comparison has been presented. The purpose of this work is to identify optimal acquisition parameters

Removal of local field gradient artifact
✍ Qing X. Yang; Gerald D. Williams; Roger J. Demeure; Timothy J. Mosher; Michael B 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 891 KB

## Abstract Development of high magnetic field MRI techniques is hampered by the significant artifacts produced by B~0~ field inhomogeneities in the excited slices. A technique, gradient‐echo slice excitation profile imaging (__GESEPI__), is presented for recovering the signal lost caused by intrav

Cardiac imaging: Comparison of two-shot
✍ Daniel A. Leung; Jörg F. Debatin; Simon Wildermuth; Graeme C. McKinnon; Gustav K 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 665 KB

## Abstract We compared the cardiac image quality of multishot echo‐planar imaging (EPI), segmented K‐space, and conventional cine acquisitions. Three techniques were used to obtain gated multiphase acquisitions of an axial section traversing both ventricles in 10 volunteers: two‐shot EPI acquired