## A new model is proposed for the prediction of vapor bubble departure diameters in saturated pool boiling. The model utilizes a force balance which follows a similar form as that used by Klausner et al. (ht. J. Heat Mass Transfir 36, 651-662 (1993)) for flow boiling. The vapor bubble growth rate
The dynamics of a boiling bubble before and after detachment
β Scribed by C. W. M. van der Geld
- Publisher
- Springer-Verlag
- Year
- 2007
- Tongue
- English
- Weight
- 830 KB
- Volume
- 45
- Category
- Article
- ISSN
- 1432-1181
No coin nor oath required. For personal study only.
π SIMILAR VOLUMES
An improved model is proposed for the prediction of departure and lift-off diameters in saturated forced convection boiling. The model utilizes a force balance similar to that proposed by Klausner et al. (ht. J. Heat Mass Trunsfer 36,651-662 (1993)). One significant improvement is that the inclinati