𝔖 Bobbio Scriptorium
✦   LIBER   ✦

The design and optimization methodology of a low-distortion sub- sample-and-hold stage for weak bio-currents

✍ Scribed by Jie Yuan; Ka Leong Tsang


Publisher
Elsevier Science
Year
2010
Tongue
English
Weight
696 KB
Volume
41
Category
Article
ISSN
0026-2692

No coin nor oath required. For personal study only.

✦ Synopsis


Current sample-and-hold (SHI) stage is important for reducing the signal distortion of bio-medical current detectors. Previous SHIs achieve high linearity only with high power consumption. This paper introduces a low-distortion switched-current (SI) sample-and-hold stage for high-performance current sampling of weak currents, by applying constant charge injection on a weakly inverted MOS transistor. The paper also introduces a methodology to design and optimize the SHI for a target signal-to-noisedistortion ratio (SNDR). A sample SHI is designed according to the methodology in a 0:35 mm CMOS process. Silicon measurements verify that the fabricated SHI meets the design targets, and can achieve above 58 dB SNDR and above 68 dB spurious-free dynamic range (SFDR) at the sampling rate of 2 kS/s for a 100 nA input current up to 1 kHz. The power consumption of the SHI is only 0:7 mW.