## Abstract For some applications in surgical implants a rough surface is desired, since the jagged surface structure assists the adhesion of bone material or surface coatings. Some implants are peened with coarse and sharp edged peening media. In order to avoid a distinct loss of fatigue strength,
The corrosion fatigue properties of surgical implants in a living body
โ Scribed by Morita, Masafumi ;Sasada, Tadashi ;Hayashi, Hitoshi ;Tsukamoto, Yukio
- Publisher
- John Wiley and Sons
- Year
- 1988
- Tongue
- English
- Weight
- 628 KB
- Volume
- 22
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
โฆ Synopsis
Fatigue fracture of artificial implants in the human body, caused by the repeated application of stress, is well documented. It is known that the fatigue strength of implant materials decreases when they are exposed under in vivo corrosion conditions. There are, however, no investigations concerning the effect of body fluids on the fatigue characteristics of commonly used biomaterials. Accordingly, fatigue tests on machined stainless-steel AISI 316, and COP alloy rods have been conducted in the right lower leg of rabbit. These specimens were pierced through the hole drilled at the middle of the tibial bone. A cyclic tensile stress of frequency 5 or 10 Hz was applied to the rods. From the results, it was found that the fatigue strength at 5 x 10(6) cycles for AISI 316 under the in vivo environment was 680 MPa compared to 830 MPa in air and similarly for COP alloy, was 680 MPa in the living body compared to 800 MPa in air. These remarkable changes in fatigue strength associated with the in vivo environments are considered to be due to the corrosive action of body fluids on the biomaterials.
๐ SIMILAR VOLUMES
The determination of the fatigue properties on small specimens is not accurate. It does not take into account the considerable scatter in fatigue properties which may arise in the implants. Therefore, testing of the properties on the actual implant is needed. The working hypothesis of the present ar
A modified surgical procedure is described to implant a microdialysis probe to sample ventricular cerebrospinal fluid (vCSF) in FVB mice. Microdialysis sampling of drugs in vCSF provides insight into drug penetration into the brain across the blood brain barrier (BBB) and the blood CSF barrier (BCB)
Single and multi-strand stainless steel and cobalt-nickel alloy wires, with strand diameters from 26 to 46 pm, were fatigue tested using a modified rotating bending test to determine what factors are most important in controlling fatigue life. The relation between cyclic strain and cyclic life was d
## Abstract A rapid, non-invasive method for the measurement of obsolute amounts of fat, protein, minerals and water in the body has been developed which is applicable to very ill patients. The patients is weighed and skinfold thickness is measured with calipers. The body contents of potassium, nit