The breaking strain of Nb3Sn in a multifilamentary superconductor
โ Scribed by C.F. Old; J.P. Charlesworth
- Publisher
- Elsevier Science
- Year
- 1976
- Tongue
- English
- Weight
- 542 KB
- Volume
- 16
- Category
- Article
- ISSN
- 0011-2275
No coin nor oath required. For personal study only.
โฆ Synopsis
Room temperature tensile testing has been carried out on a number of multifilamentary Nb3 Sn superconductivity wires. Metallographic studies of the tested wires suggest that filament cracking does not occur until strains approaching 1% have been reached. This conclusion has been confirmed for one of the wires by acoustic emission studies.
๐ SIMILAR VOLUMES
Bronze processed multifilamentary Nb3Sn superconducting wires, with a CuNb reinforcing stabilizer instead of the conventional Cu stabilizer, were fabricated. The mechanical properties and the strain dependence of the critical current Ic were evaluated at 4.2 K and a magnetic field of 15 T. A remarka
The critical current degradation of multifilamentary NbsSn superconducting composites strained mechanically at room temperature has been investigated. The experimental results show that the effects of the Nb$n layer thickness and the speci.men wire structure, such as monolithic and stranded cable on
Strain dependence of/~ of bronze-processed Nb-Hf/Cu-Sn-Ga superconductors (namely Nb3Sn superconductors fabricated with starting composite consisting of a Nb-Hf alloy core and a Cu-Sn-Ga sheath) and that of Cu-Sn-Ga/Nb-Hf superconductors (Nb3Sn superconductors fabricated with starting composite cons