The best fit method. A simple way for measuring the volume of an intracerebral haematoma
โ Scribed by C. L. Franke; C. W. M. Versteege; J. Gijn
- Publisher
- Springer
- Year
- 1988
- Tongue
- English
- Weight
- 272 KB
- Volume
- 30
- Category
- Article
- ISSN
- 0028-3940
No coin nor oath required. For personal study only.
โฆ Synopsis
A method is described in which the volumes of intracerebral haematomas were measured by a method of best-fitting circles, in 23 consecutive patients. The results were compared with computer measurements of the haematoma volumes. The two measures corresponded well: mean difference 0.14 cc (-0.5%), range -4.5 to +6.5 cc (-17 to +26%).