## Abstract Treatment of flax shive with sulfuric acid produces a carbonaceous material that has been used to remove metal ions from aqueous solution. Metal ions including Cd(II), Cu(II), Cr(III), Co(II), Ni(II), Zn(II) and Pb(II) have been investigated for kinetic behaviour and sorption capacities
The application of reticulated vitreous carbon rotating cylinder electrodes to the removal of cadmium and copper ions from solution
โ Scribed by Gavin W Reade; Peter Bond; Carlos Ponce de Leon; Frank C Walsh
- Publisher
- Wiley (John Wiley & Sons)
- Year
- 2004
- Tongue
- English
- Weight
- 345 KB
- Volume
- 79
- Category
- Article
- ISSN
- 0268-2575
No coin nor oath required. For personal study only.
โฆ Synopsis
Abstract
The removal of cadmium and cupric ions from 0.50 mol dm^โ3^ Na~2~SO~4~ at pH 2 and 298 K was studied using a reticulated vitreous carbon (RVC) rotating cylinder electrode (RCE). The cathode was a 100 pores per linear inch porosity grade with a radius of 0.5 cm, a height of 1.2 cm and a volume of 0.94 cm3. The cathode was rotated a constant speed of 1500 rev min^โ1^. A rate enhancement of approximately three times is reported for the removal of cupric ions from a chloride solution (0.05 mol dm^โ3^ cupric ions in 0.1 mol dm^โ3^ NaCl at pH 7) when compared with the analogous reaction in acid sulfate solutions (0.50 mol dm^โ3^ Na~2~SO~4~ at pH 2). SEM images of the metal deposit morphology allow the morphology of the metal deposits to be characterised. The deposits showed incomplete coverage of the RVC surface and appreciable roughness developed with time due to dendritic growths. Copyright ยฉ 2004 Society of Chemical Industry