The application of a variable-pressure scanning electron microscope with energy dispersive X-ray microanalyser to the diagnosis of electrocution: a case report
✍ Scribed by Hiroshi Kinoshita; Minori Nishiguchi; Harumi Ouchi; Takako Minami; Akira Kubota; Takao Utsumi; Nobuharu Sakamoto; Nobuyuki Kashiwagi; Kouji Shinomiya; Hideki Tsuboi; Shigeru Hishida
- Publisher
- Elsevier Science
- Year
- 2004
- Tongue
- English
- Weight
- 335 KB
- Volume
- 6
- Category
- Article
- ISSN
- 1344-6223
No coin nor oath required. For personal study only.
✦ Synopsis
We describe here a case of accidental electrocution. A 48-year-old male was found dead in his room. At autopsy, there was a current mark on the right thumb and big toe. Histological examination revealed that the skin wound had the characteristics of a current mark, including vacuolation and elongation of the cell nuclei. We could also identify titanium metallization on the skin surface of the current mark using a variable-pressure scanning electron microscope (VP-SEM) equipped with energy dispersive X-ray microanalyser (EDX). The autopsy finding and the subsequent investigation support the conclusion that the cause of his death was electrocution. Our result shows that the VP-SEM with EDX is a useful tool for the forensic diagnosis of electrocution.