𝔖 Bobbio Scriptorium
✦   LIBER   ✦

The apparent elastic modulus of the juxtaricular subchondral bone of the femoral head

✍ Scribed by Dr. Thomas D. Brown; Mark S. Vrahas


Publisher
Elsevier Science
Year
1984
Tongue
English
Weight
673 KB
Volume
2
Category
Article
ISSN
0736-0266

No coin nor oath required. For personal study only.

✦ Synopsis


An experiment was undertaken to obtain approximate values for the intrinsic elastic modulus of subchondral bone. Shallow spherical caps, with uniform and incrementally controlled thickness, were machined from subchondral bone in the weight-bearing regions of 11 fresh-frozen normal femoral head autopsy specimens. Under application of polar point loads, the measured deflections were compared with a corresponding analytical shell solution, thus allowing back-calculation of the apparent modulus. Analogous tests were performed on similarly shaped specimens of stock Plexiglas@ of known modulus in order to estimate the precision of the testing method. The aggregate results for subchondral bone showed that its intrinsic stiffness correlated inversely with nominal shell thickness, but even the thinnest (1.0 mm thick) of these shells had an apparent modulus (mean = 1.372 GN/m2, SD = 414 MN/m2) well below that generally accepted for "pure" cortical bone (about 14 GN/ m2). This stiffness deficit was very likely due to the presence of histologically evident marrow spaces. However, the low apparent modulus values measured in this study may not be fully representative of complex in vivo behavior, because in the testing of excised shells there is no radial compressive stress transfer to underlying cancellous bone.


πŸ“œ SIMILAR VOLUMES


Structural consequences of subchondral b
✍ Dr. Thomas D. Brown; Kelly J. Baker; Richard A. Brand πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 978 KB

## Abstract Appearance of a crescent sign usually marks the onset of necrotic femoral head collapse, but very little is known about which local factors contribute most critically to avoiding or postponing fracture of at‐risk juxtaarticular cancellous bone. A three‐dimensional finite element model w

Evaluation of blood flow within the subc
✍ Shinji Fukuoka; Takao Hotokebuchi; Seiya Jingushi; Hitoshi Fujii; Yoichi Sugioka πŸ“‚ Article πŸ“… 1999 πŸ› Elsevier Science 🌐 English βš– 850 KB

The laser speckle method is a new form of tissue flowmetry that can analyze the interference pattern that appears when tissue is illuminated with a laser beam. During surgery for 100 cases of osteonecrosis of the femoral head, we measured the blood flow within the subchondral bone using this method.

Assessment of subchondral bone blood flo
✍ Shinji Fukuoka; Takao Hotokebuchi; Kazumasa Terada; Nobuo Kobara; Hitoshi Fujii; πŸ“‚ Article πŸ“… 1999 πŸ› Elsevier Science 🌐 English βš– 762 KB

## Abstract The laser speckle method is a new form of flowmetry that can obtain a two‐dimensional distribution of blood flow in tissue. This method is a noncontact, simple, and rapid technique that may aid in the diagnosis of osteonecrosis. We investigated whether the subchondral bone blood flow wi