In this paper we extend some results from our earlier work [ 11, where additional The buckling of a thin clamped plate can be described by a function u (xl, x2) information about the model and its operator equation can be found. defined in a bounded domain Q ' 3 2 , being a solution of the equation
The analytic theory, optimization, and performance of transparent pulses
β Scribed by Michael H. Buonocore
- Publisher
- John Wiley and Sons
- Year
- 1992
- Tongue
- English
- Weight
- 630 KB
- Volume
- 24
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Transparent pulses are defined by the property of having no net effect on stationary spins, while selectively nutating and dephasing flowing spins. They are derived from the inverse scattering transform, a nonlinear extension of the inverse Fourier transform. They can be used as presaturation pulses to suppress selectively the signal from flowing spins. Their intended imaging application is suppression of blood flow artifacts arising from the heart and major vessels. Diastolic images of these areas have significant artifacts that hinder accurate delineation of vessel and chamber boundaries. Transparent pulses significantly improve delineation of these boundaries and therefore could be used to improve the accuracy and precision of crossβsectional area measurements. In this paper, the analytic theory, numerical optimization, and performance characteristics are described. Experimental evidence of flow signal suppression is provided in diastolic imaging of the heart in normal subjects. The long duration and power requirements of the present generation of transparent pulses currently limits their general Clinical use. Β© 1992 Academic Press, Inc.
π SIMILAR VOLUMES
The conjugate gradient method is used to optimize the inversion slice profile produced by complex hyperbolic secant selective pulses. An improved quality is obtained for the inversion slice profile at a price, however, of a lower immunity to the amplitude variation of radiofrequency pulses.
## Abstract Discrimination between signals produced by fat and by water is an important issue in MRI. One efficient approach is to perform fatβsuppression by selective inversion. This technique exploits the transition region of a selective RF pulse to invert the longitudinal lipid magnetization whi
## Abstract Spectrometers make use of D/A converters to generate RF and gradient shapes. This paper examines by exact simulations the time and amplitude digitization effects, inherent to the use of D/A converters, on the performance of amplitude modulated (AM) frequency selective RF pulses. By maki