Wood poles have been traditionally tested by "sounding" -striking with a hammer and making a subjective assessment on the basis of the sound emitted. Various other acoustic methods have been developed and employed for this function but none has been accepted on any regular basis as being successful.
Testing of poles by acoustic resonance
โ Scribed by J. I. Dunlop
- Publisher
- Springer
- Year
- 1983
- Tongue
- English
- Weight
- 383 KB
- Volume
- 17
- Category
- Article
- ISSN
- 0043-7719
No coin nor oath required. For personal study only.
โฆ Synopsis
An acoustic resonance technique has been evaluated as a means of detecting deterioration in wood poles. The basis of the technique is that degradation of the pole by rot or other agency will lead to an increase in the damping of longitudinal acoustic waves, which can subsequently be detected by an examination of the acoustic resonance characteristics of the pole. The technique was assessed in a series of field trials conducted on in-situ poles, which were subsequently removed and dissected. The results of the acoustic testing compared favourably with the gradings of the poles following dissection.