The mechanical performance of the DPC-TJ coil was measured during the charge-up test by strain gauges and displacement gauges attached directly to the coil surface. To estimate winding stiffness, expansion tests were performed on a winding model at both 300 and 77 K. The test results obtained with t
Test results of the DPC-TJ: electromagnetic performance
โ Scribed by M. Ono; H. Mukai; M. Shimada; Y. Wachi; T. Fujioka; T. Isono; K. Okuno; Y. Takahashi; M. Sugimoto; H. Hiue; F. Hosono; K. Kawano; T. Hiyama; T. Ando; H. Nakajima; T. Kato; M. Oshikiri; H. Hanawa; F. Tajiri; T. Ohuchi; M. Seki; J. Okayama; M. Nishi; H. Tsuji
- Publisher
- Elsevier Science
- Year
- 1993
- Tongue
- English
- Weight
- 545 KB
- Volume
- 33
- Category
- Article
- ISSN
- 0011-2275
No coin nor oath required. For personal study only.
โฆ Synopsis
The DPC-TJ coil experiment was successfully carried out at the Japan Atomic Research Institute (JAERI) in 1991. This coil was developed by Toshiba and JAERI in collaboration to demonstrate the realization of superconducting coils for fusion with a high average current density of 40A mm -2. The DPC-TJ coil was charged up to its rated current of 24 kA (40 A mm -2) at 7.6 T without quench in the DPC test facility. Thereafter electromagnetic performance was tested by measuring / and T values and the critical cur-
rent at 12 T Was estimated at 41 kA. Many electromagnet=c results were obtained, wh=ch are necessary for the design of future fusion machines such as the International Thermonuclear Experimental Reactor (ITER).