Abstract
This study established data demonstrating the possible laser‐welded strengths of cast Ti and Ti‐6Al‐7Nb and compared them to those of two dental‐casting alloys. Cast plates of Ti, Ti‐6Al‐7Nb, gold, and Co–Cr alloy were prepared. After polishing the surfaces to be welded, two plates were abutted and welded using an Nd:YAG laser at a pulse duration of 10 ms, spot diameter of 1 mm, and voltage of 200 V. Five specimens were prepared for each metal by welding either three or five spots unilaterally or bilaterally. The fracture load and percent elongation were measured at a crosshead speed of 1.0 mm/min. The bilaterally welded specimens performed significantly greater than unilaterally welded specimens in both fracture load and elongation whether they were welded with three or five spots per side. The bilaterally welded Ti and Ti‐6Al‐7Nb specimens were nearly as strong as their corresponding control specimens, whereas the gold and Co–Cr specimens were approximately half as strong. When a large proportion of the cross‐sectional area of the joint is laser welded, the strength of the laser‐welded portion of the cast Ti and Ti‐6Al‐7Nb may approach or equal that of the nonwelded metal frameworks. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 71B: 46–51, 2004
📜 SIMILAR VOLUMES
## Abstract __In vitro__ studies of Ti‐6Al‐7Nb and Ti‐5Al‐2Nb‐1Ta alloys were carried out by treating the specimens with 10__M__ NaOH at 60°C for 24 h and subsequently heat‐treated at 600°C for 1 h. After the alkali and heat treatments, and on subsequent soaking in simulated body fluid (SBF), the m
## Abstract The impairment of skeletal muscle microcirculation by a biomaterial may have profound consequences. Due to excellent physical and corrosion characteristics, CoCrMo‐, Ti‐6Al‐4V‐, and Ti‐6Al‐7Nb‐alloys are commonly used in orthopedic surgery. Yet concern has been raised with regard to the
## Abstract The present work reports the fabrication of self‐organized porous oxide‐nanotube layers on the biomedical titanium alloys Ti‐6Al‐7Nb and Ti‐6Al‐4V by a simple electrochemical treatment. These two‐phase alloys were anodized in 1__M__ (NH~4~)~2~SO~4~ electrolytes containing 0.5 wt % of NH
## Abstract The Ti‐6Al‐7Nb alloy has been recently developed for biomedical use, particularly for orthopedics and dental applications. Osteosynthesis has been used to analyze biocompatibility and osseoconduction properties. The interaction of the implant with its biological environment, the formati