𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Temporal characteristics of oxygenation-sensitive MRI responses to visual activation in humans

✍ Scribed by Peter Fransson; Gunnar Krüger; Klaus-Dietmar Merboldt; Jens Frahm


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
832 KB
Volume
39
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Series of single‐shot blipped echo‐planar images with spin‐density weighting and T~2~* sensitivity (2.0 T, TR = 400 ms, TE = 54 ms, flip angle = 30°) were used to study the temporal response profiles to repetitive visual activation (5 Hz, reversing black and white checkerboard versus darkness) for protocols comprising multiple cycles of a 1.6‐s stimulus in conjunction with a 8.4‐s or 90‐s recovery phase and a 10‐s stimulus with a 20‐s or 90‐s recovery phase. Analysis of the real‐time data from all activated pixels resulted in a strong positive MRI response (mean values 3‐6%) as well as a marked poststimulus undershoot (mean values 1‐2%, duration 60‐90 s) for all paradigms. Repetitive protocols with insufficient recovery periods of 8.4 s or 20 s gave rise to a wraparound effect when analyzing time‐locked averages from multiple activation cycles. This problem may lead to an early signal decrease that originates from the ongoing undershoot of preceding activations folded back into the initial latency phase of a subsequent activation. When ensuring complete decoupling of responses to successive stimuli by using a 90‐s recovery period, the wraparound effect vanished and an initial dip was observed in one of seven subjects for a 10‐S/90‐S protocol.


📜 SIMILAR VOLUMES


Stimulus dependence of oxygenation-sensi
✍ G. Krüger; A. Kleinschmidt; J. Frahm 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 117 KB

Oxygenation-sensitive MRI responses to repetitive and sustained visual activation were compared for stimuli with different temporal, spatial, and luminance contrasts, i.e. reversing checkerboard, flashing diffuse red light, and stationary diffuse gray light with darkness as a control. All paradigms

Dynamic MRI sensitized to cerebral blood
✍ Gunnar Krüger; Andreas Kleinschmidt; Jens Frahm 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 525 KB

## Abstract Changes in cerebral blood oxygenation and flow during prolonged activation of human visual cortex (6‐min video projection) were monitored using high‐resolution T~2~\*‐ and T~1~‐weighted gradient‐echo MRI in identical sessions. Oxygenation‐sensitive recordings displayed an initial signal

Activation and deactivation in response
✍ Hama Watanabe; Fumitaka Homae; Gentaro Taga 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 720 KB

## Abstract In an infant's developing cortex, the explanation for the mechanisms underlying the activations and deactivations in response to visual stimuli remains controversial. While previous near‐infrared spectroscopy (NIRS) studies in awake infants have demonstrated cortical activations in resp