๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Temperature-Programmed Packed Capillary Liquid Chromatography Coupled to Fourier-Transform Infrared Spectroscopy

โœ Scribed by Bruheim, Inge ;Molander, Paal ;Lundanes, Elsa ;Greibrokk, Tyge ;Ommundsen, Espen


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
97 KB
Volume
23
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

โœฆ Synopsis


Temperature-programmed packed capillary liquid chromatography has been coupled off-line to Fourier-transform infrared spectroscopy, utilizing a commercially available interface with a pneumatic nebulizer rebuilt to handle low flow rates at elevated temperatures. The modified interface showed excellent performance with regard to nonaqueous reversed phase separations of polymer additives, resulting in constructed Gram-Schmidt chromatograms comparable to chromatograms obtained using UV detection. The spray of the in-house constructed nebulizer was not influenced by temperature changes of the column effluent, and hence temperature-programmed gradient separations could be used successfully. The relative standard deviation of peak height was 4.4% (n = 5) and the mass limit of detection was determined to be about 40 ng, using a polymer antioxidant as model compound. The present instrumental coupling has been used for characterization of the antioxidant Irgafos P-EPQ.


๐Ÿ“œ SIMILAR VOLUMES


Evaluation of temperature programming fo
โœ O. Nordstrรถm; P. Molander; T. Greibrokk; R. Blomhoff; E. Lundanes ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 118 KB

## Abstract A miniaturized amperometric detector compatible with temperatureโ€programmed packed capillary liquid chromatography has been constructed and evaluated. Temperature programming could successfully be used as a tool for retention control, providing gradient action that did not influence the

Identification of volatile organic compo
โœ Ilkka Ojanperรค; Riikka Hyppรถlรค; Erkki Vuori ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 523 KB

A purge and trap concentrator with a Tenax trap was coupled to gas chromatography-Fourier transform infrared spectrometry for the identification of volatile organic compounds in blood samples. A styrene-divinyl benzene porous layer capillary column allowed the separation of compounds such as househo

Sheathless electrospray ionization direc
โœ Felix C. Leinweber; Dietmar G. Schmid; Dieter Lubda; Bernd Sontheimer; Gรผnther J ๐Ÿ“‚ Article ๐Ÿ“… 2004 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 181 KB

## Sheathless electrospray ionization directly from a capillary monolith for fast liquid chromatography coupled to Fourier transform ion cyclotron resonance mass spectrometry High-resolution Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) has emerged as one of the most eff