𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Temperature optimization for improved determination of phosphatidylserine species by micro liquid chromatography with electrospray tandem mass spectrometric detection

✍ Scribed by Åsmund Larsen; Paal Molander


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
428 KB
Volume
27
Category
Article
ISSN
1615-9306

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A sensitive method for determination of disaturated phosphatidylserine species in the presence of their monounsaturated analogs has been developed, using micro liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The hydrophobic nature of the phosphatidylserine species required a combination of low‐eluting sample solvents and sub‐ambient temperatures in order to focus large sample volumes up to 20 μL. The samples were dissolved in 2‐propanol : hexane : water (20 : 10 : 4, v/v/v) prior to 1 : 9 dilution with ammonium formate buffer : 2‐propanol : tetrahydrofuran (30 : 55 : 15, v/v/v) and final 1 : 4 dilution with ammonium formate buffer (10 mM) : 2‐propanol : tetrahydrofuran (55 : 37.5 : 7.5, v/v/v). The analytical column was a 0.5×150 mm stainless steel column packed with 5 μm C~30~ particles, while the mobile phase contained ammonium formate buffer (10 mM) :  2‐propanol : tetrahydrofuran (30 : 55 : 15, v/v/v). A temperature program from 5°C (hold for 3 minutes) to 75°C at 8 K/min provided separation of the disaturated phosphatidylserine species from their monounsaturated analogs, making available a sensitive determination of the isobaric species. The mass limit of detection for dipalmitoyl phosphatidylserine was 100 pg, corresponding to a concentration limit of detection of 5 pg/μL when using an injection volume of 20 μL. This is an improvement by a factor of 20 as compared to previously reported numbers obtained with conventional LC columns. The within‐assay precision of dipalmitoyl phosphatidylserine was 11.9% RSD (n = 3), while the retention time precision was 4.1% RSD (n = 6).


📜 SIMILAR VOLUMES


On-line derivatization of peptides for i
✍ M. S. Cárdenas; E. van der Heeft; A. P. J. M. de Jong 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 152 KB 👁 2 views

An on-line method has been developed for the derivatization and coupled liquid chromatography (LC)/electrospray ionization (ESI) MS analysis of peptides at the femtomol level. Peptides are reacted with N-succinimidyl-2(3-pyridyl)acetate (SPA) in buffered aqueous medium at pH 7 following loading on a

Determination of bromazepam in human pla
✍ Maristela H. Andraus; Anthony Wong; Ovandir A. Silva; Cicília Y. Wada; Odaly Tof 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 141 KB 👁 1 views

## Abstract A simple method using a one‐step liquid–liquid extraction (LLE) followed by high‐performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI‐MS/MS) detection was developed for the determination of bromazepam in human plasma, using lo

Molecular species of sphingomyelin: dete
✍ Karlsson, Anders Å.; Michélsen, Peter; Odham, Göran 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 144 KB 👁 3 views

In a sphingomyelin-enriched sample of polar lipids from bovine milk, molecular species of intact sphingomyelin were separated by normal-phase high-performance liquid chromatography and detected by mass spectrometry (MS) for structural information. First, by using electrospray with positive ionizatio

Determination of didanosine in human ser
✍ Rita de Cassia E. Estrela; Myriam C. Salvadori; Renata S. L. Raices; Guilherme S 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 164 KB 👁 2 views

## Abstract A method based on solid‐phase extraction coupled to liquid chromatography with positive ion electrospray ionization and tandem mass spectrometric detection was developed for the determination of didanosine in human serum, using lamivudine as internal standard. The acquisition was perfor