Technique for in vivo measurement of the three-dimensional kinematics and laxity characteristics of the ankle joint complex
β Scribed by Dr. Sorin Siegler; Dinghua Wang; Elizabeth Plasha; Arnold T. Berman
- Publisher
- Elsevier Science
- Year
- 1994
- Tongue
- English
- Weight
- 883 KB
- Volume
- 12
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
We introduce here a technique to measure the threeβdimensional kinematics and laxity characteristics of the ankle joint complex in vivo. The system consists of an optoelectric, kinematic data acquisition system that is used to measure the motion of the ankle joint complex in response to controlled moments applied through a system of pneumatic actuators. As a first step toward development of the method into a quantitative diagnostic tool for injuries of ankle ligaments, we addressed the following questions: (a) What is the reliability for measurement of range of motion and laxity of the ankle joint complex? (b) Are there significant differences in laxity between the left and right joints of a healthy individual? and (c) Are there significant differences in laxity of the ankle joint complex between men and women? To answer these questions, we performed repeated measures of range of motion and laxity of paired ankles in a population of 18 healthy young individuals. The high intraclass correlation coefficients obtained from the statistical analysis indicate that the new experimental system is highly reliable in measurement of total range of motion and total laxity of the ankle joint complex. We further concluded that, within the statistical power available in our experimental design, there are no significant differences in either range of motion or laxity between left and right ankles of healthy individuals or between men and women.
π SIMILAR VOLUMES
## Abstract Accurate knowledge of in vivo ankle joint complex (AJC) biomechanics is critical for understanding AJC disease states and for improvement of surgical treatments. This study investigated 6 degreesβofβfreedom (DOF) in vivo kinematics of the human AJC using a combined dualβorthogonal fluor
## Abstract Patellofemoral pain is widely accepted as one of the most common pathologies involving the knee, yet the etiology of this pain is still an open debate. Generalized joint laxity has been associated with patellofemoral pain, but is not often discussed as a potential source of patellar mal
## Abstract The objective of this study was to use an ovine stifle joint model to assess the impact of combined transection of the anterior cruciate and medial collateral ligaments on threeβdimensional (3D) joint motion serially over 20 weeks after transection. In vivo 3D kinematics were measured i