Targeted single-shot methods for diffusion-weighted imaging in the kidneys
✍ Scribed by Ning Jin; Jie Deng; Longjiang Zhang; Zhuoli Zhang; Guangming Lu; Reed A. Omary; Andrew C. Larson
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 528 KB
- Volume
- 33
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose:
To investigate the feasibility of combining the inner‐volume‐imaging (IVI) technique with single‐shot diffusion‐weighted (DW) spin‐echo echo‐planar imaging (SE‐EPI) and DW‐SPLICE (split acquisition of fast spin‐echo) sequences for renal DW imaging.
Materials and Methods:
Renal DWI was performed in 10 healthy volunteers using single‐shot DW‐SE‐EPI, DW‐SPLICE, targeted‐DW‐SE‐EPI, and targeted‐DW‐SPLICE. We compared the quantitative diffusion measurement accuracy and image quality of these targeted‐DW‐SE‐EPI and targeted DW‐SPLICE methods with conventional full field of view (FOV) DW‐SE‐EPI and DW‐SPLICE measurements in phantoms and normal volunteers.
Results:
Compared with full FOV DW‐SE‐EPI and DW‐SPLICE methods, targeted‐DW‐SE‐EPI and targeted‐DW‐SPLICE approaches produced images of superior overall quality with fewer artifacts, less distortion, and reduced spatial blurring in both phantom and volunteer studies. The apparent diffusion coefficient (ADC) values measured with each of the four methods were similar and in agreement with previously published data. There were no statistically significant differences between the ADC values and intravoxel incoherent motion (IVIM) measurements in the kidney cortex and medulla using single‐shot DW‐SE‐EPI, targeted‐DW‐EPI, and targeted‐DW‐SPLICE (P > 0.05).
Conclusion:
Compared with full‐FOV DWI methods, targeted‐DW‐SE‐EPI and targeted‐DW‐SPLICE techniques reduced image distortion and artifacts observed in the single‐shot DW‐SE‐EPI images, reduced blurring in DW‐SPLICE images, and produced comparable quantitative DW and IVIM measurements to those produced with conventional full‐FOV approaches. J. Magn. Reson. Imaging 2011;33:1517–1525. © 2011 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Partial __k__‐space sampling is frequently used in single‐shot diffusion‐weighted echo‐planar imaging (DW‐EPI) to reduce the TE and thereby improve the SNR. However, it increases the sensitivity of the technique to bulk rotational motion, which introduces a phase gradient across the tis
## Abstract ## Purpose: To determine the potential benefit of combined respiratory‐cardiac triggering for diffusion‐weighted imaging (DWI) of kidneys compared to respiratory triggering alone (RT). ## Materials and Methods: Renal DWI was performed in 17 volunteers comparing RT, combined respirato
## Abstract Diffusion‐weighted single‐shot EPI (sshEPI) is one of the most important tools for the diagnostic assessment of stroke patients, but it suffers from well known artifacts. Therefore, sshEPI was combined with SENSitivity Encoding (SENSE) to further increase EPI's potential for stroke imag
## Abstract ## Purpose: To determine if 2D single‐shot interleaved multislice inner volume diffusion‐weighted echo planar imaging (ss‐IMIV‐DWEPI) can be used to obtain quantitative diffusion measurements that can assist in the identification of plaque components in the cervical carotid artery. ##