𝔖 Bobbio Scriptorium
✦   LIBER   ✦

T2-weighted MR imaging of focal hepatic lesions: Comparison of various RARE and fat-suppressed spin-echo sequences

✍ Scribed by Richard C. Semelka; J. Patrick Shoenut; Randall M. Kroeker


Publisher
John Wiley and Sons
Year
1993
Tongue
English
Weight
482 KB
Volume
3
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The authors prospectively compared four T2‐weighted magnetic resonance (MR) sequences, including high‐resolution 512 × 512 (matrix size) RARE (rapid acquisition with relaxation enhancement), 256 × 256 RARE, 128 × 256 breath‐hold RARE, and 192 × 256 fat‐suppressed spin‐echo (T2FS) sequences, in the evaluation of 16 patients with focal hepatic masses. MR images were evaluated by quantitative lesion‐liver signal difference‐to‐noise ratios (SDNRs) and subjective evaluation of image artifact and image quality. No significant differences were observed between RARE sequences in SDNR values. The T2FS sequence had a significantly higher SDNR than the 512 × 512 RARE sequence (24.6 ± 15.0 vs 14.5 ± 9.7) (P =.008). Image quality was rated highest for the 512 × 512 RARE and T2FS sequences (P =.006). The inherent advantage of high spatial resolution suggests that the 512 × 512 RARE sequence may be of value in detecting hepatic lesions.


📜 SIMILAR VOLUMES


Hemodynamic characterization of focal he
✍ Masatoshi Hori; Takamichi Murakami; Tonsok Kim; Riccardo Iannaccone; Hisashi Abe 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 463 KB

## Abstract ## Purpose To investigate the role of ferucarbotran‐enhanced dynamic MR imaging using multishot spin‐echo echo‐planar sequence in the evaluation of hemodynamics of focal hepatic lesions. ## Materials and Methods Sixty‐three focal hepatic lesions (24 benign and 39 malignant) from 53 c

Gradient- and spin-echo T2-weighted imag
✍ Takeshi Yoshikawa; Donald G. Mitchell; Shozo Hirota; Yoshiharu Ohno; Kazushige O 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 309 KB

## Abstract ## Purpose To evaluate superparamagnetic iron oxide (SPIO)‐enhanced breathhold T2‐weighted GRASE imaging in detection and characterization of focal liver lesions. ## Materials and Methods In 30 patients (including 20 with cirrhosis) with 39 malignant and 25 benign lesions, gradient‐

Comparison of ferucarbotran-enhanced flu
✍ Yoshihiko Fukukura; Takuro Kamiyama; Koji Takumi; Toshikazu Shindo; Ryutaro Higa 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 291 KB

## Abstract ## Purpose: To compare the diagnostic accuracy of superparamagnetic iron oxide (SPIO)‐enhanced fluid‐attenuated inversion‐recovery echo‐planar imaging (FLAIR EPI) for malignant liver tumors with that of T2‐weighted turbo spin‐echo (TSE), T2\*‐weighted gradient‐echo (GRE), and diffusion