T1ρ-prepared balanced gradient echo for rapid 3D T1ρ MRI

✍ Scribed by Walter R.T. Witschey; Arijitt Borthakur; Mark A. Elliott; Matthew Fenty; Matthew A. Sochor; Chenyang Wang; Ravinder Reddy


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
731 KB
Volume
28
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To develop a T1ρ‐prepared, balanced gradient echo (b‐GRE) pulse sequence for rapid three‐dimensional (3D) T1ρ relaxation mapping within the time constraints of a clinical exam (<10 minutes), examine the effect of acquisition on the measured T1ρ relaxation time and optimize 3D T1ρ pulse sequences for the knee joint and spine.

Materials and Methods

A pulse sequence consisting of inversion recovery–prepared, fat saturation, T1ρ‐preparation, and b‐GRE image acquisition was used to obtain 3D volume coverage of the patellofemoral and tibiofemoral cartilage and lower lumbar spine. Multiple T1ρ‐weighted images at various contrast times (spin‐lock pulse duration [TSL]) were used to construct a T1ρ relaxation map in both phantoms and in the knee joint and spine in vivo. The transient signal decay during b‐GRE image acquisition was corrected using a k‐space filter. The T1ρ‐prepared b‐GRE sequence was compared to a standard T1ρ‐prepared spin echo (SE) sequence and pulse sequence parameters were optimized numerically using the Bloch equations.

Results

The b‐GRE transient signal decay was found to depend on the initial T1ρ‐preparation and the corresponding T1ρ map was altered by variations in the point spread function with TSL. In a two compartment phantom, the steady state response was found to elevate T1ρ from 91.4 ± 6.5 to 293.8 ± 31 and 66.9 ± 3.5 to 661 ± 207 with no change in the goodness‐of‐fit parameter R^2^. Phase encoding along the longest cartilage dimension and a transient signal decay k‐space filter retained T1ρ contrast. Measurement of T1ρ using the T1ρ‐prepared b‐GRE sequence matches standard T1ρ‐prepared SE in the medial patellar and lateral patellar cartilage compartments. T1ρ‐preparedb‐GRE T1ρ was found to have low interscan variability between four separate scans. Mean patellar cartilage T1ρ was elevated compared to femoral and tibial cartilage T1ρ.

Conclusion

The T1ρ‐prepared b‐GRE acquisition rapidly and reliably accelerates T1ρ quantification of tissues offset partially by a TSL‐dependent point spread function. J. Magn. Reson. Imaging 2008;28:744–754. © 2008 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


In vivo T1ρ mapping in cartilage using 3
✍ Xiaojuan Li; Eric T. Han; Reed F. Busse; Sharmila Majumdar 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 585 KB

## Abstract For __T__~1ρ~ quantification, a three‐dimensional (3D) acquisition is desired to obtain high‐resolution images. Current 3D methods that use steady‐state spoiled gradient‐echo (SPGR) imaging suffer from high SAR, low signal‐to‐noise ratio (SNR), and the need for retrospective correction

Rapid 3D-T1ρ mapping of the knee joint a
✍ S. Kubilay Pakin; Jian Xu; Mark E. Schweitzer; Ravinder R. Regatte 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 462 KB

## Abstract Three‐dimensional spin‐lattice relaxation time in the rotating frame (3D‐T~1ρ~) with parallel imaging at 3.0T was implemented on a whole‐body clinical scanner. A 3D gradient‐echo sequence with a self‐compensating spin‐lock pulse cluster was combined with generalized autocalibrating part

Impact of motion on T1 mapping acquired
✍ Ueli Studler; Lawrence M. White; Gustav Andreisek; Sheena Luu; Hai-Ling Margaret 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 109 KB 👁 1 views

## Abstract ## Purpose: To evaluate the impact of motion on T1 values acquired by using either inversion‐recovery fast spin echo (IR‐FSE) or three‐dimensional (3D) spoiled gradient recalled‐echo (SPGR) sequences for delayed gadolinium‐enhanced magnetic resonance imaging of cartilage (dGEMRIC) in v

Feasibility of T mapping for the evaluat
✍ Bernd Bittersohl; Harish S. Hosalkar; Tim Hughes; Young-Jo Kim; Stefan Werlen; K 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 488 KB

## Abstract This study defines the feasibility of utilizing three‐dimensional (3D) gradient‐echo (GRE) MRI at 1.5T for __T__ mapping to assess hip joint cartilage degenerative changes using standard morphological MR grading while comparing it to delayed gadolinium‐enhanced MRI of cartilage (dGEMRIC